AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 51
: A = U.K., Netherlands, Luxembourg, Belgium / B = Germany, Sweden, Spain, Portugal, Italy, Switzerland, Finland, Denmark, Norway / C = France
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C
S
W
63
1
CI receive number to 
shift to non-V.34 
communication
Bit No.
1
2
2 times
1
1
1
Does not shift.
0
0
1 times
0
1
2
2  times
1
0
0
0
0
3 times
1
1
3
CI send number to shift 
to non-V.34 
communication
Binary input
2
0
0
0
4
Bit  No.
Set range
3
4
5
0 to 7 times
When N=0, retrain is not 
made.
1
1
1
5
0
0
0
6
Inhibited to use
0
0
0
7
1
1
1
8
1
1
1
S
W
64
1
Inhibited to use
0
0
0
2
1
1
1
3
0
0
0
4
0
0
0
5
0
0
0
6
1
1
1
7
1
1
1
8
0
0
0
S
W
65
1
Inhibited to use
0
0
0
2
0
0
0
3
0
0
0
4
0
0
0
5
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
66
1
Inhibited to use
0
0
0
2
0
0
0
3
0
0
0
4
0
0
0
5
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
67
1
Make time (10PPS) 
setup
Binary input
33ms (A, C)
41ms (B)
0
1
0
2
Bit  No.
Set range
1
2
3
4
26 to 41ms 
by increment of 1ms
1
1
1
3
1
1
1
4
1
1
1
5
Inhibited to use
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0
S
W
68
1
Line open delay time in 
dial test
Bit No.
1
2
2sec
0
0
0
2sec
0
0
3sec
0
1
2
4sec
1
0
0
0
0
5sec
1
1
3
Inhibited to use
0
0
0
4
0
0
0
5
T1 timer setup
Binary input
40sec
0
0
0
6
Bit  No.
Set range
5
6
7
8
30 to 105sec
5sec interval
0
0
0
7
1
1
1
8
0
0
0
Page of 127