AL-1566 (serv.man17). Service manual - Sharp Copying Equipment Service Manual (repair manual). Page 121

Read Sharp AL-1566 (serv.man17) Service Manual online

AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 45
: A = U.K., Netherlands, Luxembourg, Belgium / B = Germany, Sweden, Spain, Portugal, Italy, Switzerland, Finland, Denmark, Norway / C = France
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
A B C
S
W
31
1
Report output 
(in transmission)
Bit No.
1
2
Only when 
transmission is 
failed.
1
1
1
Refer to User program 
“PRINT 
SELECTION”.
When a value outside 
the set range is set, 
the initial value is set.
Print inhibited
0
0
All print
0
1
2
Only when 
transmission is failed.
1
0
0
0
0
1
1
3
Report output 
(In broadcast and 
sequential send 
request)
Bit No.
3
4
All print
0
0
0
Refer to User program 
“PRINT 
SELECTION”.
When a value outside 
the set range is set, 
the initial value is set.
Print inhibited
0
0
All print
0
1
4
Only the address to 
which transmission is 
failed
1
0
1
1
1
1
1
5
Report output 
(in reception)
Bit No.
5
6
Print inhibited
0
0
0
Refer to User program 
“PRINT 
SELECTION”.
When a value outside 
the set range is set, 
the initial value is set.
Print inhibited
0
0
All print
0
1
6
Only in error
1
0
0
0
0
1
1
7
Contents of send 
document are printed in 
memory send
Bit No.
7
8
Only the address 
to which 
transmission is 
failed
1
1
1
Refer to User program 
“PRINT 
SELECTION”.
When a value outside 
the set range is set, 
the initial value is set.
Print inhibited
0
0
All print
0
1
8
Only the address to 
which transmission is 
failed
1
0
0
0
0
1
1
S
W
32
1
Inhibited to use
0
0
0
2
0
0
0
3
0
0
0
4
0
0
0
5
0
0
0
6
Index print setup
1: Print
0: Not print
Not print
0
0
0
Refer to User program 
“INDEX PRINT”.
7
Inhibited to use
0
1
1
8
0
0
0
S
W
33
1
Page number print 
setup
1: Yes
0: No
Yes
1
1
1
2
Inhibited to use
0
0
0
3
0
0
0
4
0
0
0
5
0
0
0
6
0
0
0
7
0
0
0
8
Reception data duplex 
print
1: Yes
0: No
No
0
0
0
Refer to User program 
“DUPLEX RCV”.
S
W
34
1
Flash send wait time 
(U.K., Netherlands, 
Luxembourg, Belgium, 
France: Inhibited to use)
Bit No.
1
2
1sec
0
1
0
0sec
0
0
0.5sec
0
1
2
1sec
1
0
0
0
0
2sec
1
1
3
Inhibited to use
0
0
0
4
0
0
0
5
Signal send level Max.
Binary input
–8dBm
1
1
1
6
Bit  No.
Set range
5
6
7
8
0 (0dBm) to 15 (–15dBm)
0
0
0
7
0
0
0
8
0
0
0
Page of 127
Display