AL-1556/1566  TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES  10 - 47
S
W
41
1
Number of times of 
recall in busy
Binary input
2 times
0 Refer to User program 
“RECALL TIMES 
(BUSY)”.
When a value outside 
the set range is set, 
the initial value is set.
2
Bit  No.
Set range
1
2
3
4
5
6
7
8
0 to 10 times
0
3
0
4
0
5
0
6
0
7
1
8
0
S
W
42
1
Inhibited to use
0
2
FAX receive auto select 
by CNG detection
1: Allow
0: Inhibit
Allow
1
Refer to User program 
“FAX SIGNAL AUTO 
RECEIVE”.
3
Auto receive select in 
answering telephone 
connection mode
1: Allow
0: Inhibit
Inhibit
0
Refer to Main menu 
“AM MODE”.
4
Inhibited to use
1
5
0
6
0
7
0
8
V.34 mode function in 
manual communication
1: ON
0: OFF
ON
1
S
W
43
1
V.34 mode function
1: ON
0: OFF
ON
1
2
Busy tone detection 
level table
1: variable (SRAM)
0: constant (ROM)
constant (ROM)
0
3
V.34 primary channel 
return mode
1: PPh
0: Sh
PPh
1
4
V.34 receive symbol 
speed mask
Bit No.
4
5
6
3429
1
When a value outside 
the set range is set, 
the initial value is set.
2400
0
0
0
2743
0
0
1
5
2800
0
1
0
0
3000
0
1
1
6
3200
1
0
0
1
3429
1
0
1
7
Silence detection level 
table
1: variable (SRAM)
0: constant (ROM)
constant (ROM)
0
8
Control channel retrain 
judgment in V.34 
reception
1: Ignore EQM value
0: Judge EQM value
Judge EQM value 0
S
W
44
1
V.34 primary channel 
send speed
Binary input
33600bps
1
2
Bit  No.
Send speed =
2400 (bps) x N
1
2
3
4
When N = 0, 2400bps.
When N = 15, 33600bps.
1
3
1
4
0
5
V.34 primary channel 
receive speed
Binary input
33600bps
1
6
Bit  No.
Receive speed =
2400 (bps) x N
5
6
7
8
When N = 0, 2400bps.
When N = 15, 33600bps.
1
7
1
8
0
S
W
45
1
FAST mode
1: Yes
0: No
No
0
2
Sequence of year/
month/day in LCD, 
report, and sender 
record
Bit No.
2
3
Day/Month/Year
1
Refer to User program 
“DATE&TIME 
FORMAT SET”.
When a value outside 
the set range is set, 
the initial value is set.
Year/Month/Day
0
0
Month/Day/Year
0
1
3
Day/Month/Year
1
0
0
1
1
4
Time display format
1: am/pm
0: 24H
24H
0
Refer to User program 
“DATE&TIME 
FORMAT SET”.
5
Scan effective image 
area main scan right 
edge image loss (SPF)
Binary input
96 dots
0
6
Bit  No.
Set range
5
6
7
8
0 to ± 360 dots
24 dot interval
1
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 127