AL-1556/1566 TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 48
∗
: A = U.K., Netherlands, Luxembourg, Belgium / B = Germany, Sweden, Spain, Portugal, Italy, Switzerland, Finland, Denmark, Norway / C = France
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
∗
Remark
A B C
S
W
46
1
Specification of print
sequence in duplex print
sequence in duplex print
1: Print order (214365...)
0: Reception order
(123456...)
(123456...)
Print order
(214365...)
1
1
1
2
Specification of rotating
direction duplex back
surface print
direction duplex back
surface print
1: 180 degrees rotation
0: No 180 degrees rotation
180 degrees
rotation
1
1
1
3
Priority in the day of
week
week
1: Yes
0: No
No (A)
Yes (B, C)
0
1
1
4
Center No. in FAST
mode
mode
1: Host-Tel-No.
0: Service-No.
Service-No.
0
0
0
5
Summer time
1: Allow
0: Inhibit
Allow
1
1
1
Refer to Entry Mode
“DAY LIGHT
SAVING”.
“DAY LIGHT
SAVING”.
6
PBX setting
(U.K., Netherlands,
Luxembourg, Belgium:
Inhibited to use)
(U.K., Netherlands,
Luxembourg, Belgium:
Inhibited to use)
Bit No.
6
7
8
Setting OFF
0
0
0
Refer to User program
“PBX SETTING
MODE”.
When a value outside
the set range is set,
the initial value is set.
“PBX SETTING
MODE”.
When a value outside
the set range is set,
the initial value is set.
Setting OFF
0
0
0
7
Flash send
1
0
1
0
0
0
ID send
1
1
0
8
0
0
0
S
W
47
1
Inhibited to use
1
1
1
2
External telephone
connection
connection
1: Yes
0: No
Yes
1
1
1
3
Inhibited to use
0
0
0
4
0
0
0
5
0
0
0
6
1
1
1
7
0
0
0
8
0
0
0
S
W
48
1
Tone/Pulse default
setup
setup
Bit No.
1
2
TONE
1
1
1
01 (20PPS) is invalid
except for Japan.
Refer to User program
“DIAL MODE”.
When a value outside
the set range is set,
the initial value is set.
except for Japan.
Refer to User program
“DIAL MODE”.
When a value outside
the set range is set,
the initial value is set.
10PPS
0
0
20PPS
0
1
2
TONE
1
0
0
0
0
1
1
3
Telephone line menu
1: Inhibit
0: Allow
Inhibit
1
1
1
4
DP dial pulse number
process
process
1: 10-N
0: Normal (N)
Normal (N)
0
0
0
5
Scan effective image
area main scan left
edge image loss (SPF)
area main scan left
edge image loss (SPF)
Binary input
96 dots
0
0
0
6
Bit No.
Set range
Set range
5
6
7
8
0 to 360 dots
24 dot interval
24 dot interval
1
1
1
7
0
0
0
8
0
0
0
S
W
49
1
Inhibited to use
0
0
0
2
0
0
0
3
Speaker sound volume
pattern number in
DTMF send
pattern number in
DTMF send
Binary input
21
0
0
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
4
Bit No.
Set range
Set range
3
4
5
6
7
8
Pattern No. 1 to 35
0
0
0
5
0
0
0
6
0
0
0
7
0
0
0
8
1
1
1
S
W
50
1
Line monitor volume
Bit No.
1
2
Medium
1
1
1
When SPEAKER key
is pressed, user
setting can be made.
is pressed, user
setting can be made.
Silent
0
0
Small
0
1
2
Medium
1
0
0
0
0
Large
1
1
3
Line monitor volume
pattern number
pattern number
Binary input
16
0
0
0 When a value outside
the set range is set,
the initial value is set.
the initial value is set.
4
Bit No.
Set range
Set range
3
4
5
6
7
8
Pattern No. 1 to 35
1
1
1
5
0
0
0
6
0
0
0
7
0
0
0
8
0
0
0