4. Camera E-E Audio Level Check (2)
Mode
Camera E-E
Signal
70Hz, -6dBs signal:
1kHz, -6dBs signal:
20kHz, -6dBs signal:
Left and right terminal of MIC/LINE
jack
Measurement Point
Audio left or right terminal of
AUDIO/VIDEO jack
Measuring Instrument
Audio level meter, digital volt meter
Specified Value
-4.0 
±
 2.0dBs
Switch setting:
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by “2. Overall Level
Characteristics Check”
Checking Method:
1)
Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 0Vdc. (Do not connect the audio oscillator
and attenuator.)
Mode
Camera E-E (HDV1080i)
Signal
70Hz, -6dBs signal:
1kHz, -6dBs signal:
20kHz, -6dBs signal:
Left and right terminal of MIC/LINE
jack
Measurement Point
Audio left or right terminal of
AUDIO/VIDEO jack
Measuring Instrument
Audio level meter, digital volt meter
Specified Value
-4.0 
±
 3.0dBs
Switch setting:
REC FORMAT (IN/OUT REC menu) ......................... HDV1080i
MIC/LINE( AUDIO SET menu) ........................................... LINE
AUDIO SELECT .......................................................... MANUAL
AUDIO LEVEL .......................... Position set by “2. Overall Level
Characteristics Check”
Checking Method:
1)
Check that the DC voltage of the left and right terminal of
MIC/LINE jack is 0 
±
 0.1Vdc. (Do not connect the audio
oscillator and attenuator.)