Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online
— 20 —
HDR-FX1/FX1E
Before change
After change
Page 6-42
Page 6-43
33. Color Reproduction Check ND 2 SD STD
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note4) (Fig. 6-1-20.)
signal level (A) to 90 IRE.
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 90 IRE.
is 90 IRE.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-20.)
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A) is
90 IRE (NTSC) or 88 IRE (PAL).
90 IRE (NTSC) or 88 IRE (PAL).
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV, 88 IRE = 616 mV
34. Color Reproduction Check
ND OFF SD CINE
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE. (Note6)
(Fig. 6-1-22.)
signal level (A) to 70 IRE. (Note6)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 70 IRE.
is 70 IRE.
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
luminance points is set in each
color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE (NTSC)
or 68 IRE (PAL). (Note6)
(Fig. 6-1-22.)
signal level (A) to 70 IRE (NTSC)
or 68 IRE (PAL). (Note6)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
luminance points is set in each
color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
70 IRE = 490 mV, 68 IRE = 476 mV
: Changed portion
Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man9) service manuals if exist.