HDR-FX1, HDR-FX1E (serv.man9) - Sony Movie Service Manual (repair manual). Page 20

Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online

— 20 —
HDR-FX1/FX1E
Before change
After change
Page 6-42
Page 6-43
33. Color Reproduction Check ND 2 SD STD 
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 90 IRE.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
90 IRE = 630 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A) is
90 IRE (NTSC) or 88 IRE (PAL).
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
90 IRE = 630 mV, 88 IRE = 616 mV
34. Color Reproduction Check
ND OFF SD CINE 
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE. (Note6)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 70 IRE.
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “OFF”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note5)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE (NTSC)
or 68 IRE (PAL). (Note6)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Note5: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note6: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV, 68 IRE = 476 mV
 : Changed portion
Page of 25
Display