Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online
— 19 —
HDR-FX1/FX1E
Before change
After change
Page 6-41
31. Color Reproduction Check
ND OFF SD STD
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to “DV”.
2
Set ND FILTRE switch to
“OFF”.
“OFF”.
3
0
01
01
Set the data.
4
6
01
4D
Set the data, and press PAUSE
button.
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note5) (Fig. 6-1-20.)
signal level (A) to 90 IRE.
(Note5) (Fig. 6-1-20.)
6
6
9E
22
Set the data.
7
6
12
80
Set the data.
8
6
12
00
Set the data.
9
Check that the Y signal level (A)
is 90 IRE.
is 90 IRE.
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV
Page 6-42
Adjusting method:
Order Page Address Data
Procedure
1
Set REC FORMAT to “DV”.
2
Set ND FILTRE switch to
“OFF”.
“OFF”.
3
0
01
01
Set the data.
4
6
01
4D
Set the data, and press PAUSE
button.
button.
5
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note5) (Fig. 6-1-20.)
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note5) (Fig. 6-1-20.)
6
6
9E
22
Set the data.
7
6
12
80
Set the data.
8
6
12
00
Set the data.
9
Check that the Y signal level (A) is
90 IRE (NTSC) or 88 IRE (PAL).
90 IRE (NTSC) or 88 IRE (PAL).
10
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV, 88 IRE = 616 mV
32. Color Reproduction Check ND 1 SD STD
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE.
(Note4) (Fig. 6-1-20.)
signal level (A) to 90 IRE.
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A)
is 90 IRE.
is 90 IRE.
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
01
4D
Set the data, and press PAUSE
button.
button.
4
6
9D
Change the data and set the Y
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-20.)
signal level (A) to 90 IRE
(NTSC) or 88 IRE (PAL).
(Note4) (Fig. 6-1-20.)
5
6
9E
22
Set the data.
6
6
12
80
Set the data.
7
6
12
00
Set the data.
8
Check that the Y signal level (A) is
90 IRE (NTSC) or 88 IRE (PAL).
90 IRE (NTSC) or 88 IRE (PAL).
9
Check that each center of all
color luminance points is set in
each color reproduction frame.
color luminance points is set in
each color reproduction frame.
Note4: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75
Ω
.
90 IRE = 630 mV, 88 IRE = 616 mV
: Changed portion