HDR-FX1, HDR-FX1E (serv.man9) - Sony Movie Service Manual (repair manual). Page 18

Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online

— 18 —
HDR-FX1/FX1E
Before change
After change
Page 6-34
1-3.
CAMERA SYSTEM ADJUSTMENTS
22. White Balance Check ND OFF
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
COMPONENT
Display data of
connector
page 1 (Note2)
Measuring Instrument
Vectorscope
Adjustment remote
(LV5152)
commander
Specified Value 1
Fig. 6-1-13 (A)
Specified Value 2
Fig. 6-1-13 (B)
Specified Value 3
8000 to 8B80
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video termial of
Display data of
AUDIO/VIDEO
page 1 (Note2)
jack
Measuring Instrument
NTSC or PAL
Adjustment remote
vectorscope
commander
Specified Value 1
Fig. 6-1-13 (A)
Specified Value 2
Fig. 6-1-13 (B)
Specified Value 3
8000 to 8B80
Page 6-35
23. White Balance Check ND 1
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
COMPONENT
Display data of
connector
page 1 (Note2)
Measuring Instrument
Vectorscope
Adjustment remote
(LV5152)
commander
Specified Value 1
Fig. 6-1-14 (A)
Specified Value 2
Fig. 6-1-14 (B)
Specified Value 3
8000 to 8B80
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video termial of
Display data of
AUDIO/VIDEO
page 1 (Note2)
jack
Measuring Instrument
NTSC or PAL
Adjustment remote
vectorscope
commander
Specified Value 1
Fig. 6-1-14 (A)
Specified Value 2
Fig. 6-1-14 (B)
Specified Value 3
8000 to 8B80
Page 6-36
24. White Balance Check ND 2
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
COMPONENT connector
Measuring Instrument
Vectorscope (LV5152)
Specified Value 1
Fig. 6-1-15 (A)
Specified Value 2
Fig. 6-1-15 (B)
Subject
Clear chart
(HD color bar standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
NTSC or PAL vectorscope
Specified Value 1
Fig. 6-1-15 (A)
Specified Value 2
Fig. 6-1-15 (B)
 : Changed portion
Page of 25
Display

Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man9) service manuals if exist.