HDR-FX1, HDR-FX1E (serv.man9) - Sony Movie Service Manual (repair manual). Page 21

Read Sony HDR-FX1 / HDR-FX1E (serv.man9) Service Manual online

— 21 —
HDR-FX1/FX1E
Before change
After change
Page 6-44
Page 6-44
35. Color Reproduction Check ND 1 SD CINE 
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE. (Note5)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 70 IRE.
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “1”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE (NTSC)
or 68 IRE (PAL). (Note5)
(Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all color
luminance points is set in each
color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV, 68 IRE = 476 mV
 : Changed portion
36. Color Reproduction Check ND 2 SD CINE 
γ
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE.
(Note5) (Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A)
is 70 IRE.
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV
Adjusting method:
Order Page Address Data
Procedure
1
Set ND FILTRE switch to “2”.
2
0
01
01
Set the data.
3
6
8A
04
Set the data.
4
6
9B
Check that bit3 is “1”. (Note4)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
9D
Change the data and set the Y
signal level (A) to 70 IRE
(NTSC) or 68 IRE (PAL).
(Note5) (Fig. 6-1-22.)
7
6
9E
22
Set the data.
8
6
12
80
Set the data.
9
6
12
00
Set the data.
10
Check that the Y signal level (A) is
70 IRE (NTSC) or 68 IRE (PAL).
11
Check that each center of all
color luminance points is set in
each color reproduction frame.
Note4: For the bit values, refer to “6-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.
Note5: The Y signal terminal (Pin 1) of the COMPONENT connector
must be terminated at 75 
.
70 IRE = 490 mV, 68 IRE = 476 mV
Page of 25
Display

Click on the first or last page to see other HDR-FX1 / HDR-FX1E (serv.man9) service manuals if exist.