XG-P25XE (serv.man12). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 22

Read Sharp XG-P25XE (serv.man12) Service Manual online

XG-P25X
57
TROUBLE SHOOTING TABLE FOR PC I/F UNIT 
(Continued)
The DVI analog signals are SOG-separated by 
CXA3516R. The Green signal is fed to the SOGIN2 
terminal. The DVI SOG sync signal is selected using the 
bus switch (IC23).
Checking the DVI SOG circuit
Is there the horizontal sync 
signal at TL8082?
Is there the Green signal at pin 
(135) of IC8004?
IC8004 or its peripheral 
parts defective.
DVI connector or its peripheral 
parts defective.
Is there the sync signal at 
TL8136?
Are the signals at pin (4) of 
IC8023 and pin (4) of IC8336 
both at low level?
IC8001 defective.
IC8023 or IC8336 defective.
The DVI SOG circuit is okay.
YES
YES
YES
NO
NO
YES
NO
NO
Page of 22