TROUBLE SHOOTING TABLE FOR PC I/F UNIT 
(Continued)
6
NO
NO
NO
YES
YES
YES
7
Measure the VPC (IC8338) 
clock signal at TL8004.
Measure the signal at TL8140 
on the oscilloscope screen. 
(Check the vertical sync 
signal.)
Measure the signal at 
TL8142 on the oscilloscope 
screen. (Check the 
horizontal sync signal.)
Is the clock signal as 
specified?
Go to "Checking the video 
sync signal".
IC8338 defective.
IC8025 or its peripheral 
parts defective.
Checking the video sync 
signal
Is the vertical sync 
signal as specified?
Is the horizontal sync 
signal as specified?
Go to "Checking the input 
signal settings".
Input PWB defective.