XG-P25XE (serv.man12). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 20

Read Sharp XG-P25XE (serv.man12) Service Manual online

XG-P25X
55
TROUBLE SHOOTING TABLE FOR PC I/F UNIT 
(Continued)
Feed the DVI digital signal to the 
INPUT3 terminal.
Note: To ensure the Plug&Play system, first connect 
the cable to the INPUT3 terminal and then turn on 
the computer (signal generator) power.
Select INPUT3 for input terminal.
Checking the DVI digital input
Does the image appear?
Is the image free from distortion?
Are the colors as specified?
The DVI digital input is okay.
IC8298 or its peripheral 
parts defective.
Measure the vertical sync signal at 
the land of C8463 and the 
horizontal sync signal at the land 
of C8484. (The capacitors are 
located on the back of the PWB.)
Are the sync signals as specified?
Measure the clock signal at 
R8685 (located on the back of 
the PWB).
Is the clock signal as specified?
IC8299 or its peripheral parts 
defective.
Is the signal at the R4 
terminal at low level?
IC8298 or its peripheral 
parts defective.
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO