XG-P25XE (serv.man12). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 14

Read Sharp XG-P25XE (serv.man12) Service Manual online

XG-P25X
49
TROUBLE SHOOTING TABLE FOR PC I/F UNIT 
(Continued)
Checking the GA4 and its 
peripheral parts
Measure the signals at 
FB8004, FB8005 and 
FB8006 on the oscilloscope 
screen.
Select R, G and B individually 
from the process mode 
pattern menu.
Measure the signals at 
TL8106, TL8107, TL8108, 
TL8109, TL8110 and TL8111 
on the oscilloscope screen.
Are the R, G and B video 
output signals as specified?
GA4 checking ended.
Are the signals selected on 
the pattern menu and those 
being measured just the 
same?
Output PWB defective.
Are there clock signals at 
pins (31), (32) and (33) of 
IC8051?
Is there the 32.5-MHz 
clock signal at 
TP8114?
IC8029 defective.
Is there the 32.5-MHz 
clock signal at 
FB8110?
IC8025 defective.
X8005 defective.
Are the signals selected on 
the pattern menu and those 
being measured just the 
same?
IC8029 defective.
IC8025 defective.
YES
YES
NO
NO
NO
YES
YES
YES
NO
NO
YES
NO
Page of 22