XG-P25XE (serv.man12). Troubleshooting table - Sharp Projector Service Manual (repair manual). Page 21

Read Sharp XG-P25XE (serv.man12) Service Manual online

XG-P25X
56
TROUBLE SHOOTING TABLE FOR PC I/F UNIT 
(Continued)
Feed the DVI analog signal to the 
INPUT3 terminal.
Select INPUT3 for the input 
terminal.
Checking the DVI analog input
Does the image appear?
Is the image distorted?
See if there are the R, G and B 
signals at pins (126), (136) and 
(141) of IC8004.
Are there the R, G and B signals?
DVI connector or its peripheral 
parts defective.
Are the sync signals of 
separation type?
Check the DVI SOG circuit.
Check the vertical sync signal and 
the horizontal sync signal at pin (6) 
of IC8330 and pin (6) of IC8331, 
respectively.
Are the sync signals as 
specified?
Are there the horizontal and 
vertical sync signals at TL8130 
and TL8131?
Sync separation circuit IC8330 or 
IC8331 defective.
IC8302 or its peripheral parts 
defective.
IC8025, IC8004 or their 
peripheral parts defective.
3
NO
NO
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO