E-63
Maintenance &
Tr
oubleshooting
Lamp/Maintenance Indicators
Maintenance Indicators
TEMPERATURE
WARNING
indicator
LAMP
REPLACEMENT
indicator
POWER
indicator
Problem
• Blocked air intake.
• Clogged air filter.
• Cooling fan breakdown.
• Internal circuit failure.
• Burnt-out lamp.
• Lamp circuit failure.
• The filter cover is open.
Maintenance Indicator
The internal
temperature is
abnormally high.
TEMPERATURE
WARNING indicator
LAMP REPLACE-
MENT indicator
POWER indicator
The lamp does not
light up.
The POWER
indicator blinks in
red when the
projector is on.
Condition
Possible Solution
• Relocate the projector to an area with
proper ventilation.
• Clean the filter.
(See page 
66
.)
• Take the projector to your nearest Sharp
Authorized LCD Projector Dealer or Service
Center for repair.
• Carefully replace the lamp. (See pages 
64
and 
65
.)
• Take the projector to your nearest Sharp
Authorized LCD Projector Dealer or Service
Center for repair.
• Securely install the filter cover.
• If the POWER indicator blinks even when
the filter cover is securely installed, contact
your nearest Sharp Authorized LCD
Projector Dealer or Service Center for
advice.
• The warning lights on the projector indicate problems
inside the projector.
• There are two warning lights: a TEMPERATURE
WARNING indicator which warns that the projector is
too hot, and a LAMP REPLACEMENT indicator which
lets you know when to change the lamp.
• If a problem occurs, either the TEMPERATURE
WARNING indicator or the LAMP REPLACEMENT
indicator will light up red. After turning off the power,
follow the procedures given below.
• If the TEMPERATURE WARNING indicator lights up, follow the above possible solutions and then wait until the projector has
cooled down completely before turning the power back on. (At least 5 minutes.)
• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be
triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet and put it back
in again.
The lamp requires
replacement.
• Lamp has been used for
over 1,400 hours.
Lamp
The lamp in this projector operates for approximately 1,500 cumulative hours, depending on the usage environ-
ment. It is recommended that the lamp be replaced after 1,400 cumulative hours of use or when you notice a
significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
Display. (see page 
51
.)
CAUTION
• Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.
• As the usage environment can vary significantly, the projector lamp may not operate for 1,500 hours.
• For safety, the power will not be turned on from the fourth times when turning on the power without changing the lamp after
use for 1,500 hours.
Problem
• Lamp has been used for over 1,400
hours.
• Lamp has been used for over 1,500
hours.
Possible Solution
• Purchase a replacement lamp unit
(lamp/cage module) of the current
type BQC-XGP25X//1 from your
nearest Sharp Authorised LCD
Projector Dealer or Service Center.
• Replace the lamp. (See pages 
64
and 
65
.) If you wish, you may
have the lamp replaced at your
nearest Sharp Authorised LCD
Projector Dealer or Service Center.
Condition
The LAMP REPLACEMENT
indicator lights up red, and “LAMP”
and “ ” will blink in yellow in the
lower-left corner of the picture.
A significant deterioration of the
picture and color quality occurs.
The power will automatically turn
off and the projector will enter
standby mode.
“LAMP” and “ ” will blink in red in
the lower-left corner of the picture,
and the power will turn off.
E-64
Maintenance &
Tr
oubleshooting
Replacing the Lamp
It is recommended that the lamp be replaced after approximately 1,400 cumulative hours of use or when you
notice a significant deterioration of the picture and color quality. Carefully change the lamp by following the steps
below.
If the new lamp does not light after replacement, take your projector to the nearest Sharp Authorized LCD Projector
Dealer or Service Center for repair. Purchase a replacement lamp unit (lamp/cage module) of the current type
BQC-XGP25X//1 from your nearest Sharp Authorized LCD Projector Dealer or Service Center. Then carefully change
the lamp by following the instructions below. If you wish, you may have the lamp replaced at your nearest Sharp
Authorized LCD Projector Dealer or Service Center.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this
projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized LCD Projector
Dealer or Service Center. For the name of the nearest Sharp Authorized LCD Projector Dealer or Service Center,
please call toll-free: 1-888-GO-SHARP (1-888-467-4277).   
                                                                                             U.S.A. ONLY
CAUTION
• Potential hazard of glass particles if lamp ruptures. In case of lamp rupture, contact your nearest
Sharp Authorized LCD Projector Dealer or Service Center for a replacement.
• Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely
hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage
to fully cool before removing the lamp cage.
Caution Concerning the Lamp
• This projector utilizes a pressurized mercury lamp. A loud sound may indicate lamp failure. Lamp failure can
be attributed to numerous sources such as excessive shock, improper cooling, surface scratches or deterioration
of the lamp due to a lapse of usage time. The period of time up to failure largely varies depending on the
individual lamp and/or the condition and the frequency of use. It is important to note  that failure can often result
in the bulb cracking.
• When the LAMP REPLACEMENT indicator and on-screen display icon is illuminated or blinks, it is recommended
that the lamp be replaced with a new one immediately, even if the lamp appears to be operating normally.
• Should the lamp break, the glass particles may spread inside the lamp cage or gas contained in the lamp may
be vented into the room from the exhaust vent. Because the gas in this lamp includes mercury, ventilate the
room well if the lamp breaks and avoid all exposure to the released gas. In case of exposure to  the gas, consult
with a doctor as soon as possible.
• Should the lamp break, there is also a possibility that glass particles may spread inside of the projector. In such
a case, it is recommended you contact your nearest Sharp Authorized LCD Projector Dealer or Service Center
to remove the damaged lamp and assure safe operation.
1
Turn off the
power.
Press POWER OFF.
Wait until the cooling
fan stops.
• Be sure to remove the lamp cage by the handle. Be sure not to touch the glass surface of the lamp cage or the inside of
the projector.
• To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below.
• Be sure to change the air filter during lamp replacement. The air filter comes packaged with the lamp unit.
Removing and installing the lamp unit
CAUTION
2
Disconnect the
power cord.
Unplug the power cord
from the AC socket.
3
Remove the
bottom filter cover.
Turn over the projector.
Press the tab and lift
open the filter cover in
the direction of the
arrow.
4
Remove the
air filter.
Grasp the air filter
between your fingers
and lift it out of the filter
cover.
Tab
E-65
Maintenance &
Tr
oubleshooting
Replacing the Lamp
10
Attach the lamp cage
cover.
Slide the lamp cage cover in
the direction of the arrow. Then
tighten the user service screw.
User service screw
9
Insert the new lamp cage.
Press the lamp cage firmly into
the lamp cage compartment.
Fasten the securing screws.
8
Remove the lamp
cage.
Remove the securing screws
from the lamp cage. Hold the
lamp cage by the handle and
pull it towards you.
1
Connect the power
cord.
Reset the lamp timer.
While pressing ƒ, © and
ENTER on the projector, press
POWER ON on the projector.
Plug the power cord into the AC
socket of the projector.
Resetting the lamp timer
“LAMP 0000H” is displayed,
indicating that the lamp timer is
reset.
2
• Reset the lamp timer only after replacing the lamp.
Securing
screw
Securing
screws
7
Remove the lamp cage
cover.
Turn over the projector and
loosen the user service screw
that secures the lamp cage
cover. Then slide the cover in
the direction of the arrow.
User service screw
6
5
Replace the air filter.
Replace the filter
cover.
Insert the tab on the end of the
filter cover into the filter cover
opening and press the filter
cover into position.
Place the air filter underneath the
tabs on the filter frame.
Tab
E-66
Maintenance &
Tr
oubleshooting
• This projector is equipped with two air filters to ensure the optimal operating condition of the projector.
• The air filters should be cleaned every 100 hours of use. Clean the filters more often when the projector is used
in a dusty or smoky location.
• Have your nearest Sharp Authorized LCD Projector Dealer or Service Center exchange the filter (PFILD0080CEZZ)
when it is no longer possible to clean it.
Replacing the Air Filter
4
6
Clean the air filter.
5
Replace the air filter.
1
3
Turn off the power and
disconnect the power
cord.
2
Remove the bottom
filter cover.
Grasp the air filter between your
fingers and lift it out of the filter
cover.
Turn over the projector. Press the
tab and lift open the filter cover
in the direction of the arrow.
Remove the air filter.
Insert the tab on the end of the
filter cover into the filter cover
opening and press the filter
cover into position.
Place the air filter underneath
the tabs on the filter frame.
Clean the dust off the air filter
and cover with a vacuum
cleaner extension hose.
Cleaning and replacing the bottom air filter
• Be sure the filter cover is securely installed. The power will not turn on unless it is correctly installed.
Cleaning the side air filter (not removable)
If dust or dirt has collected inside the air filter, clean the filter with a vacuum cleaner extension hose.
Replace the filter
cover.
• The side air filter cannot be removed.
Bottom View
Side and Rear View
Air filter
Air filter (not removable)
Tab
Tab
Press POWER OFF. Wait until
the cooling fan stops.
Page of 6
Display

Download Sharp XG-P25XE (serv.man36) User Guide / Operation Manual

Here you can read online and download Sharp XG-P25XE (serv.man36) User Guide / Operation Manual in PDF. XG-P25XE (serv.man36) user guide / operation manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XG-P25XE (serv.man36) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.