MX-M364N, MX-565N (serv.man4). Service Manual (Revised January 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 107

Read Sharp MX-M364N / MX-565N (serv.man4) Service Manual online

MX-M565N  SIMULATION  5 – 7
3. Details of simulation
 
1
 
1-1
Purpose
Operation test/check
Function (Purpose)
Check the operation of the scanner (read-
ing) unit and the control circuit.
Section
Scanner (reading)
Operation/Procedure
1)
Select the operation resolution (scan speed) with the touch
panel key.
2)
Press [EXECUTE] key.
Scanning is once performed at the speed corresponding to the
scan resolution (operation speed).
 
1-2
Purpose
Operation test/check
Function (Purpose)
Check the sensors in the scanner (reading)
section and the related circuits.
Section
Scanner
Operation/Procedure
The operating status of the sensor is displayed. When "MHPS" is
highlighted, the scanner unit is in the home position.
 
1-5
Purpose
Operation test/check
Function (Purpose)
Check the operation of the scanner (read-
ing) unit and the control circuit.
Section
Scanner (reading)
Operation/Procedure
1)
Select the operation speed with the touch panel key.
2)
Press [EXECUTE] key.
Scanning is repeated at the speed corresponding to the scan
resolution (operation speed). When [EXECUTE] key is
pressed, the operation is terminated.
 
2
 
2-1
Purpose
Operation test/check
Function (Purpose)
Check the operations of the automatic doc-
ument feed unit and the control circuit.
Section
Automatic document feeder
Operation/Procedure
1)
Select the operation mode and the speed with the touch panel
key.
2)
Press [EXECUTE] key.
The DSPF repeats paper feed, transport, and paper exit oper-
ations at the speed corresponding to the scan resolution (oper-
ation speed).When [EXECUTE] key is pressed, the operation
is terminated.
DSPF
RSPF
 
2-2
Purpose
Operation test/check
Function (Purpose)
Check the operations of the sensors and
the detectors in the document feed unit
section and the control circuits.
Section
Automatic document feeder
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played. The code names of the sensors and the detectors which
are active are highlighted.
Item/Display
Operation mode
Default value
OC SCAN
300DPI
300DPI (372mm/s)
300DPI 
(372mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
1200DPI
1200DPI (93mm/s)
Item/Display
Operation mode
Default value
OC SCAN
300DPI
300DPI (372mm/s)
300DPI 
(372mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
1200DPI
1200DPI (93mm/s)
Item/Display
Operation mode
Default value
 (SINGLE)
300DPI
300DPI (372mm/s)
300DPI 
(372mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
(DOUBLE)
300DPI
300DPI (372mm/s)
300DPI 
(372mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
Item/Display
Operation mode
Default value
 (SINGLE)
300DPI
300DPI (279mm/s)
300DPI 
(279mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
(DOUBLE)
300DPI
300DPI (279mm/s)
300DPI 
(279mm/s)
400DPI
400DPI (279mm/s)
600DPI
600DPI (186mm/s)
SSET
SPF installation detector
SOCD
SPF open/close detector
SCOV
SPF upper door open/close detector
SLCOV
SPF lower door open/close sensor
SPED1
SPF document upper limit detector
SPED2
SPF document empty detector
SPPD1
SPF document pass detector 1 
(Paper entry detection)
SPPD2
SPF document pass detector 2 
(Resist roller front document transport detection)
SPPD3
SPF document pass detector 3 
(Document scanning front document transport detection)
SPPD4
SPF document pass detector 4
SPPD5
SPF document pass detector 5 
(Document transport detection) 
SPOD
SPF document exit detector
SPRDMD
SPF document random detector
SPLS1
SPF document length detection short detector
SPLS2
SPF document length detection long detector
STLD
SPF document feed tray lower limit detector
STUD
SPF document feed tray upper limit detector
STMPU
SPF stamp unit installation detector
SWD_LEN
SPF guide plate position (Unit: 0.1mm)
SWD_AD
SPF document detection volume output AD value
Page of 127
Display