Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual online
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 53
Process control
Enable/Disable
setting
Enable/Disable
setting
D
HUM_LIMIT
HUM judgment is made when turning
ON the power and after passing TIME.
ON the power and after passing TIME.
Color process control
Enable
Enable
0 - 2
0
0
Process control Disable
1
BK process control
Enable
Enable
2
Process control
Enable/Disable
setting
Enable/Disable
setting
E
HUM
The temperature and humidity in side
the machine are monitored only during a
job for every 2hours (set by item N).
When the changes in the temperature
and the humidity are greater than the
specified level (the set value of item O)
in comparison with the previous process
control.
the machine are monitored only during a
job for every 2hours (set by item N).
When the changes in the temperature
and the humidity are greater than the
specified level (the set value of item O)
in comparison with the previous process
control.
Color process control
Enable
Enable
0 - 2
0
0
Process control Disable
1
BK process control
Enable
Enable
2
F
REV1
YES
The accumulated traveling distance of
BK or M position OPC unit reaches the
specified level after turning the power.
BK or M position OPC unit reaches the
specified level after turning the power.
Enable
0 - 1
0
0
NO
Inhibit
1
G
REV2_BK
YES
The accumulated traveling distance of
BK position OPC drum unit reaches the
specified level from execution of the
previous density correction.
BK position OPC drum unit reaches the
specified level from execution of the
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
H
REV2_CL
YES
The accumulated traveling distance of M
position OPC drum unit reaches the
specified level from execution of the
previous density correction.
position OPC drum unit reaches the
specified level from execution of the
previous density correction.
Enable
0 - 1
0
0
NO
Inhibit
1
I
REFRESH MODE
(Not used)
(Not used)
YES
Select of YES/NO of the manual process
control key with key operation
control key with key operation
Key operation display
0 - 1
0
1
NO
Key operation NO
display
display
1
Process control
conditions setting
conditions setting
J
DAY
When the next warm-up if there is no
color job after a color job after passing
the specified days from execution of the
previous color process control
color job after a color job after passing
the specified days from execution of the
previous color process control
Disable of the specified
days judgment
days judgment
0 - 999
0
1
1 - 999 days passing
1 - 999
K
PIX_RATIO_BK
Magnification ratio setting (%) of the BK toner count specified value
entry of 100 corresponds to 1k of A4 5% print.
entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
L
PIX_RATIO_CL
Magnification ratio setting (%) of the color (CMY) toner count
specified value entry of 100 corresponds to 1k of A4 5% print.
specified value entry of 100 corresponds to 1k of A4 5% print.
1 - 999
10
M
INTERVAL TIME
Passing time setting of "TIME" (h: hour)
1-255
(1-255: 1-255h passed)
12
N
HUM HOUR
Interval setting of the temperature and humidity monitoring time of
"HUM" (h: hour)
"HUM" (h: hour)
1 - 24
2
O
HUM_DIF
Area difference specified value when compared with the execution
of the previous process control of "HUM”
of the previous process control of "HUM”
1 - 9
2
P
BK_RATIO
Magnification ratio setting (%) of the specified value of the BK
position OPC drum traveling distance of "REV2_BK”
position OPC drum traveling distance of "REV2_BK”
1-999
(Entry of 20 corresponds
to 100,000mm.)
15
Q
M_RATIO
Magnification ratio setting (%) of the M position OPC drum traveling
distance of "REV2_CL”
distance of "REV2_CL”
1-999
(Entry of 20 corresponds
to 100,000mm.)
10
R
COLOR BORDER
Magnification ratio setting (%) of the M
position OPC drum traveling distance
when executing the BK process control
position OPC drum traveling distance
when executing the BK process control
0 - 999
0
20
1 - 999(%)
1 - 999
S
BK ONLY
Disable/Enable setting and setting of the
number of repetition of the BK process
control when monochrome print is
continued.
number of repetition of the BK process
control when monochrome print is
continued.
Enable 5 time
0 - 6
0
5
Disable 1-5 times
1 - 5
Inhibit
6
T
HT_DIF
Bias change difference value used for judgment of HT process
control
control
1 - 255
40
Registration
adjustment
setting
adjustment
setting
U
RG_ON_SYNC
CL
Select of synchronous/asynchronous of the power ON process
control
control
0 - 2
0
0
ALL
1
CL/BK
2
V
RG_TEMP_TIMER
Execution timing setting after turning ON the power
0 - 240 (MINUTE)
0
W
RG_PERM_TIMER
Span setting from execution Disable to Enable
0 - 15 (HOUR)
1
X
RG_HOUR_TIMER
Span setting of timer execution
0-15 (Above)+(HOUR)
5
Secondary
transfer cleaning
setting
transfer cleaning
setting
Y
2TRAN_CLEAN_TIME1
Secondary transfer cleaning process time judgment threshold
value 1
value 1
1 - 999
200
Z
2TRAN_CLEAN_TIME2
Secondary transfer cleaning process time judgment threshold
value 2
value 2
1 - 999
300
AA
2TRAN_CLEAN_TIME3
Secondary transfer cleaning process time judgment threshold
value 3
value 3
1 - 999
500
Mode
Item/Display
Content
Setting range
Default
value