Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual online
MX-C400P/C380P, MX-B400P/B380P/B382P SIMULATION 5 – 49
(*1) Differs depending on the destination.
(*2) Value on the left: Voltage level after correction
Value on the right: Base voltage level
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photo-conductor/Develop-
ing)
ing)
Operation/Procedure
1)
Select a display mode. (Select a display mode button, and
press [OK] key.)
press [OK] key.)
44-13
Purpose
Adjustment/Setup
Function (Purpose)
Used to perform the color image sensor
(image registration sensor F) calibration.
(image registration sensor F) calibration.
Section
Operation/Procedure
1)
Select [EXECUTE] button, and press [OK] key.
The shutter plate of the color image density sensor (image reg-
istration sensor F) is opened, and the message indicating that
the primary transfer unit is removed is displayed.
istration sensor F) is opened, and the message indicating that
the primary transfer unit is removed is displayed.
2)
Open the front cabinet of the machine and remove the waste
toner box and the primary transfer unit.
toner box and the primary transfer unit.
3)
Install the calibration jig (UKOG-0318FCZZ) of the color image
density sensor (image registration sensor F) to the sensor
housing section.
density sensor (image registration sensor F) to the sensor
housing section.
4)
Set the waste toner box, and close the right cover unit (sec-
ondary transfer unit section) and the front cabinet of the
machine.
ondary transfer unit section) and the front cabinet of the
machine.
5)
Select [EXECUTE] button, and press [OK] key.
Calibration of the color image density sensor (image registration
sensor F) is automatically performed. After completion of the oper-
ation, the adjustment result is displayed and [EXECUTE] button is
returned to the normal display.
sensor F) is automatically performed. After completion of the oper-
ation, the adjustment result is displayed and [EXECUTE] button is
returned to the normal display.
OTHER
CRUM
DESTINATION
Machine side management CRUM destination
(Main unit data)
(Main unit data)
-
CRUM
information
(*1)
MODEL TYPE
Machine model type
0 - 1
0
CRUM DEST_K
CRUM destination (CRUM data)
-
CRUM
information
(*1)
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT
PROCON COUNT HV
High density process control number of
executions
executions
0 - 99999999
0
PROCON COUNT HT
Halftone process control number of executions
0 - 99999999
0
Mode
Item/Display (*: Correction value)
Content
Display
range
Default
value
Mode
Item/Display
Content
Display
range
Default
value
TARGET
(1 page)
CARB DATA
Calibration plate
detection level
detection level
0 - 255
108
SEAL ADJ
DATA
DATA
Jig patch seal
detection level when
executing SIM 44-13
detection level when
executing SIM 44-13
1 - 255
108
ADK_SL (K)
Development
characteristics
gradient coefficient
(High density process
control operation)
characteristics
gradient coefficient
(High density process
control operation)
-9.99 -
9.99
0
ADK_INT(K)
Development
characteristics
intercept level (High
density process
control operation 0V)
characteristics
intercept level (High
density process
control operation 0V)
-999.9 -
999.9
0
TARGET (K)
High density process
control target density
level (K)
control target density
level (K)
0.00 -
255.00
0
TARGET
(C/M/Y)
(C/M/Y)
High density process
control target density
level (C/M/Y)
control target density
level (C/M/Y)
0.00 -
255.00
0
PATCH
1-5
(Page 1-2)
n-1
High density process
control nth time patch
density level 1 (n=1-
5)
control nth time patch
density level 1 (n=1-
5)
0 - 255
0
n-2
Patch data nth time
patch 2 (n=1-5)
patch 2 (n=1-5)
0 - 255
0
n-3
Patch data nth time
patch 3 (n=1-5)
patch 3 (n=1-5)
0 - 255
0
n-4
Patch data nth time
patch 4 (n=1-5)
? BK only
patch 4 (n=1-5)
? BK only
0 - 255
0
n-5
Patch data nth time
patch 5 (n=1-5)
? BK only
patch 5 (n=1-5)
? BK only
0 - 255
0
PATCH
6-10
(Page 1-2)
n-1
Patch data nth time
patch 1 (n=6-10)
patch 1 (n=6-10)
0 - 255
0
n-2
Patch data nth time
patch 2 (n=6-10)
patch 2 (n=6-10)
0 - 255
0
n-3
Patch data nth time
patch 3 (n=6-10)
patch 3 (n=6-10)
0 - 255
0
n-4
Patch data nth time
patch 4 (n=6-10)
? BK only
patch 4 (n=6-10)
? BK only
0 - 255
0
n-5
Patch data nth time
patch 5 (n=6-10)
? BK only
patch 5 (n=6-10)
? BK only
0 - 255
0
Item/Display
Content
Setting
range
Default
value
A
PCS_CL CARB OUT
Calibration plate
sensor value
sensor value
1 - 255
108
B
PCS_CL LED ADJ
Color sensor light
emitting quantity
adjustment value
emitting quantity
adjustment value
1 - 255
21
Error display
Content
SEN ADJ ERR
Color sensor adjustment error
SHUTTER OPEN ERR
Separation operation error
ERROR
Forcible stop
Mode
Item/Display
Content
Display
range
Default
value
3
‘16/Apr
3
3
3
Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.