MX-C380P, MX-C400P, MX-B380P, MX-B382P, MX-B400P (serv.man6). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 122

Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual online

MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 48
 
44-9
Purpose
Operation data display
Function (Purpose) Used to display the result data of the high
density process control operation.
Section
Image process (Photo-conductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select a target display mode. (Select a display mode button,
and press [OK] key.)
Mode
Item/Display (*: Correction value)
Content
Display 
range
Default 
value
CPY/PRN 
(*2)
P (PROCON)
BLACK : GB ***/***  DV ***/***
High density process control GB/DV data 
(KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 630
DV: 430
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
N(M)
(NORMAL (MIDDLE))
BLACK : GB ***/***  DV ***/***
High density normal (Medium speed display) GB/
DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 630
DV: 430
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
N(L)
(NORMAL (LOW))
BLACK : GB ***/***  DV ***/***
High density normal (Low speed display) GB/DV 
data (KCMY)
(Actual output voltage level/base voltage level)
GB: 230 - 850
DV: 0 - 700
GB: 600
DV: 400
CYAN : GB ***/***  DV ***/***
MAGENTA : GB ***/***  DV ***/***
YELLOW : GB ***/***  DV ***/***
OTHER
TN/TC
TN HUD AREA
Toner control display humidity area
1 - 14
9
TN HUD DATA
Toner control display humidity AD value
0 - 1023
0
TC TMP AREA
Transfer display temperature area
1 - 9
4
TC TMP DATA
Transfer display temperature AD value
0 - 1023
0
TC HUD AREA
Transfer display humidity area
1 - 9
4
TC HUD DATA
Transfer display humidity AD value
0 - 1023
0
MD HUD AREA
Membrane decrease display humidity area
1 - 14
9
MD HUD DATA
Membrane decrease display humidity AD value
0 - 1023
0
DRUM
MD K STEP
Drum membrane decrease correction STEP 
display (KCMY)
0 - 4
0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER
Membrane decrease drum traveling distance 
area (KCMY)
0 - 20
0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
VG
MD K REVISE(VG) : L ***  M ***
Drum membrane decrease grid voltage 
correction display (KCMY)
0 - 255
0
MD C REVISE(VG) : L ***  M *** 
MD M REVISE(VG) : L ***  M *** 
MD Y REVISE(VG) : L ***  M *** 
LD
MD K REVISE(LD) : L ***  M *** 
Drum membrane decrease laser power voltage 
correction (KCMY)
0 - 255
0
MD C REVISE(LD) : L ***  M ***
MD M REVISE(LD) : L ***  M ***
MD Y REVISE(LD) : L ***  M ***
HV
MD K REVISE(HV) : L ***  M ***
High density membrane decrease environment 
GB correction display (KCMY)
0 - 255
0
MD C REVISE(HV) : L ***  M ***
MD M REVISE(HV) : L ***  M ***
MD Y REVISE(HV) : L ***  M ***
CP
MD K REVISE(CP) : L ***  M *** 
Drum membrane decrease environment grid 
voltage correction display (KCMY)
0 - 255
0
MD C REVISE(CP) : L ***  M ***
MD M REVISE(CP) : L ***  M ***
MD Y REVISE(CP) : L ***  M ***
DL
MD K REVISE COL (DL): L ***  M *** 
Drum membrane decrease discharge light 
quantity correction (%)
0 - 100
50
MD C REVISE COL (DL): L ***  M ***
MD M REVISE COL (DL): L ***  M ***
MD Y REVISE COL (DL): L ***  M ***
DL EV
MD K REVISE COL (DL EV): L ***  M *** 
Drum membrane decrease environment 
discharge light quantity correction (%)
-100 - 100
0
MD C REVISE COL (DL EV): L ***  M ***
MD M REVISE COL (DL EV): L ***  M ***
MD Y REVISE COL (DL EV): L ***  M ***
Page of 127