MX-C380P, MX-C400P, MX-B380P, MX-B382P, MX-B400P (serv.man6). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 121

Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual online

MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 47
 
44-4
Purpose
Setting
Function (Purpose) Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set.
2) Set the set value. (Enter the set value, and press [OK] key and
OSA shortcut key.)
NOTE: Set the items to the default values unless a change is spe-
cially required.
• MX-C400P/C380P
• MX-B400P/B380P/B382P
 
44-6
Purpose
Adjustment
Function (Purpose) Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Select [EXECUTE] button, and press [OK] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed. 
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
G
REG_R LED ADJ
Image density sensor light 
emitting quantity 
adjustment value
1 - 255
32
H
REG_R DARK
Image density sensor dark 
voltage
0 - 255
0
I
REG_R GRND
Belt base detection level 
when completion of Item 
G adjustment
0 - 256
0
J
REG_R BELT MAX
Maximum value of belt 
base detection level
0 - 255
0
K
REG_R BELT MIN
Minimum value of belt 
base detection level
0 - 255
0
L
REG_R BELT DIF
Belt base detection level 
difference (Item J - Item K)
0 - 255
0
M
REG_R PATCH (K)
Patch detection level for 
check
0 - 255
0
Error name
Error content
Image density sensor 
adjustment abnormality
PCS_K LED ADJ error 
The target is not reached by 3 times of retry.
Substrate scan abnormality
PCS_K GRND error 
Effective difference between the upper and 
lower values of the belt substrate circuit, 
outside the range
Registration sensor R 
adjustment abnormality
REG_R LED ADJ error 
The target is not reached by 3 times of retry.
Registration substrate R 
scan abnormality
REG_R GRND error 
Effective difference between the upper and 
lower values of the belt substrate circuit, 
outside the range
Item/Display
Content
Setting 
range
Default 
value
A
PCS_CL TARGET
Color sensor target set 
value
1 - 255
98
B
PCS_K TARGET
Black sensor target set 
value
1 - 255
208
C
LED_CL OUTPUT
Color sensor light 
emitting quantity set 
value
1 - 255
21
D
LED_K OUTPUT
Black sensor light 
emitting quantity set 
value
1 - 255
21
E
PCS ADJSTMENT 
LIMIT
Sensor adjustment 
target limit value
1 - 255
4
F
BELT GROUND DIF
Effective difference 
between the belt 1 circuit 
substrate upper and 
lower limit values
1 - 255
1
G
BIAS_CL 
STANDARD DIF
Bias (for color) reference 
calculation difference
0 - 255
60
H
BIAS_BK 
STANDARD DIF
Bias (for black) 
reference calculation 
difference
0 - 255
0
I
BIAS PATCH 
INTERVAL
Patch bias output 
interval
1 - 255
60
Display/Item
Content
Range
Default
J
Y_PAT TARGET ID
Patch density standard 
value (yellow)
1 - 255
115
K
M_PAT TARGET ID
Patch density standard 
value (magenta)
1 - 255
124
L
C_PAT TARGET ID
Patch density standard 
value (cyan)
1 - 255
111
M
K_PAT TARGET ID
Patch density standard 
value (black)
1 - 255
4
N
HV BK_GROUND 
LIMIT
Patch position substrate 
light receiving effective 
range value
1 - 255
60
Item/Display
Content
Setting 
range
Default 
value
A
PCS_K TARGET
Image density sensor 
target set value
1 - 255
208
B
LED_K OUTPUT
Image density sensor 
light emitting quantity 
set value
1 - 255
32
C
PCS ADJSTMENT 
LIMIT
Sensor adjustment 
target limit value
1 - 255
4
D
BELT GROUND DIF
Effective difference 
between the belt 1 
circuit substrate upper 
and lower limit values
1 - 255
1
E
BIAS_BK 
STANDARD DIF
Bias I reference 
calculation difference
0 - 255
0
F
BIAS PATCH 
INTERVAL
Patch bias output 
interval
1 - 255
60
G
K_PAT TARGET ID
Patch density standard 
value I
1 - 255
4
H
HV BK_GROUND 
LIMIT
Patch position substrate 
light receiving effective 
range value
1 - 255
60
Result display
Content description
COMPLETE
Normal complete
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Item/Display
Content
Setting 
range
Default 
value
1
: ’11/Mar/15
1
Page of 127
Display