Read Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man22) Technical Bulletin online
No. : CCE-1124
Date : Mar. 5, 2013
C
Document Systems Division
1/2
SHARP CORPORATION
TECHNICAL BULLETIN
COUNTERMEASURE FOR "L4-16" TROUBLE
DUE TO MALFUNCTION OF PRESSURE
RELEASE DETECT ACTUATOR
DUE TO MALFUNCTION OF PRESSURE
RELEASE DETECT ACTUATOR
1. Model Name:
MX-C310/C311/C312/C380/C381/C400/C401, DX-C310/C311/C400/C401
MX-C380P/C400P, MX-C382SC/C402SC, MX-B381/B401, MX-B380P/B400P
MX-C31FU/C31FU1/C32FU/C32FU1
2. Symptom:
The malfunction is caused by the mounting hole of Pressure release detect actuator of
fusing unit being shrank due to the influence of the heat etc, which may result in "L4-16"
trouble.
3. Description:
As the countermeasure for the malfunction because of the shrinkage of mounting hole of
Pressure release detect actuator, the diameter of the mounting hole of Pressure release
detect actuator has been changed from φ5 to φ5.05.
- Pressure release detect actuator
Before change: φ5.0
After change: φ5.05
After change: φ5.05
"A4" is engraved on modified parts.
2/2
4. Action:
From February 2013 production
5. Parts Action:
Ref.
No.
Model
name
Version P/G No.
Current parts
New parts
Price
rank
Q'ty
Parts name
Effective
time
Inter-
change-
ability
Parts code
Parts code
1
MX-C310
MX-C311
MX-C312
MX-C380
MX-C381
MX-C400
MX-C401
DX-C310
DX-C311
DX-C400
DX-C401
MX-C380P
MX-C400P
MX-B380P
MX-B400P
MX-C382SC
MX-C402SC
MX-B381
MX-B401
MX-C311
MX-C312
MX-C380
MX-C381
MX-C400
MX-C401
DX-C310
DX-C311
DX-C400
DX-C401
MX-C380P
MX-C400P
MX-B380P
MX-B400P
MX-C382SC
MX-C402SC
MX-B381
MX-B401
ALL
18-16
16-16
25-16
19-16
16-16
25-16
19-16
MLEVP1112FCA3 MLEVP1112FCA4 AN
1
Pressure release
detect actuator
detect actuator
2013/2
3
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Display