MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 50
: ’11/Mar/15
1
 
44-14
Purpose
Operation data display
Function (Purpose) Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
• MX-C400P/C380P, MX-B400P/B380P
• MX-B382P
 
44-16
Purpose
Operation data display
Function (Purpose) Used to display the toner density control
data.
Section
Developing system
Operation/Procedure
1)
Select a target color.
The toner density control data are displayed.
Select [NEXT] button and press [OK] key to switch the display
category.
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller 
thermistor (center section) 
detection temperature (
C), 
differential input AD value
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller 
thermistor compensation 
sensor (center section) 
detection temperature (
C), 
AD value
Temperature: 
0.0 - 255.0
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller 
thermistor detection sensor 
(center section) AD value
AD value: 0 - 1023
TH_LM
Fusing lower heat roller 
thermistor (side section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX1
Fusing external heat roller 
thermistor (center section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_EX2
Fusing external heat roller 
thermistor (side section) A/D 
value, temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D 
value, temperature (
C)
Temperature: 
-40.0
C - 60.0 (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D 
value, humidity (%)
Humidity: 
5.0 - 90.0% (
0.1%)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value, 
temperature (
C)
Temperature: 
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
Item/Display
Content
Display range
TH_UM
Fusing upper heat roller 
thermistor (main) detection 
temperature (
C), differential 
input AD value
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_UM_AD1
Fusing upper heat roller 
thermistor compensation 
sensor (main) detection 
temperature (
C), AD value
Temperature: 
0.0 - 255
C (0.2C)
AD value: 0 - 1023
TH_UM_AD2
Fusing upper heat roller 
thermistor detection sensor 
(main) AD value
AD value: 0 - 1023
TH_UA
Fusing upper heat roller 
thermistor (all) A/D value, 
temperature (
C)
Temperature: 
0 - 255
C (1C)
AD value: 0 - 1023
TH_M
Temperature sensor A/D 
value, temperature (
C)
Temperature: 
-40.0 - 60.0
C (1C)
AD value: 0 - 1023
HUD_M
Temperature sensor A/D 
value, humidity (%)
Temperature: 
5.0 - 90.0
C (0.1C)
AD value: 0 - 1023
TH1_LSU
LSU thermistor 1 A/D value, 
temperature (
C)
Temperature: 
5.0 - 60.0
C (0.1C)
AD value: 0 - 255
1
1
Item/
Display
Content
Setting 
range
Default 
value
TONER 
DEN_LT (M)
The current toner density sensor 
output value (final value) at the 
medium speed
1 - 255
129
TONER 
DEN_ST (M)
The current toner density reference 
value display (including all the 
correction values) at the medium 
speed
128
TONER 
DEN_LT (L)
The current toner density sensor 
output value (final value) at the low 
speed
129
TONER 
DEN_ST (L)
The current toner density reference 
value display (including all the 
correction values) at the low speed
128
Item/Display
Content
Setting 
range
Default 
value
AUTO DEVE 
(M)
Auto 
development 
adjustment 
value 
(At the 
medium 
speed)
Sensor output value 
after completion of 
SIM25-02
(at the medium 
speed)
1 - 255
128
ALL (M)
All the 
correction 
reference 
values 
(At the 
medium 
speed)
Correction reference 
value which 
calculated all the 
correction values for 
the auto 
development 
adjustment value 
(at the medium 
speed)
AUTO DEVE 
(L)
Auto 
development 
adjustment 
value 
(At the low 
speed)
Sensor output value 
after completion of 
SIM25-02
(at the low speed)
ALL (L)
All the 
correction 
reference 
values 
(At the low 
speed)
Correction reference 
value which 
calculated all the 
correction values for 
the auto 
development 
adjustment value 
(at the low speed)
AREA
Area 
correction 
value
Correction value for 
the environment 
area
-127 - 
127
0
HUD
Humidity 
correction 
value
Correction value for 
change in humidity
PRINT RATE
Print ratio 
correction 
value
Correction value for 
document print ratio
PROCON
Process 
control 
correction 
value
Correction value for 
high density process 
control result
LIFE
Life 
correction 
value
Correction value for 
the developer life
Page of 127
Display

Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.