AR-PE1 (serv.man39). ARPE1-004 ARPE1 System Software Installation System Software Patch - Sharp Copying Equipment Technical Bulletin (repair manual). Page 4

Read Sharp AR-PE1 (serv.man39) Technical Bulletin online

Sharp Electronics (UK) Ltd., NIS Systems Support
NIS Bulletin 024.doc
Page:  4 of 4
Action Performed by the ARPE1 Fiery Controller during a Ghost Image System Software Re-Installation
Start Time For each
Action
(Minutes)
Action Being Performed
ARPE1 LCD Panel Display
Connected Monitor Display
Hold down the right lower button whilst powering on the ARPE1. From
the service menu, select “Restore Backup”
Select Yes and click the button next to OK.
Restore backup Configuration ?  Yes/No
Starting MS-DOS
Select Yes and click the button next to OK.
All data will be deleted. Continue ? Yes/No
Starting MS-DOS
0
A Ghost Image is copied from the “D” drive of the ARPE1 to the other
partitions of the ARPE1
Restoring System
Ghost software displays that a ghost image is being loaded on to the ARPE1.
(The ghost image software runs twice).
5
The ARPE1 automatically reboots itself.
6
Interrupts / hardware / and memory are tested at re-boot and then the
Loading
Standard NT Load up screens
(NTDetect, OSLoader, Blue boot up screen)
7
The ARPE1 automatically reboots itself.
7
Interrupts / hardware / and memory are tested at re-boot and then the
Standard NT Load up screens
(NTDetect, OSLoader, Blue boot up screen)
X4 Background is displayed and CTRL-ALT-Delete for logon.
9
The NT System boots to a logon screen.
Loading
Service Control Manager highlights that a service has failed to load.
10
in an idle ready condition.
Idle
Fiery X4 Background Picture
Page of 4
Display

Download Sharp AR-PE1 (serv.man39) Technical Bulletin