AR-M700 (serv.man26). Setting and adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 43

Read Sharp AR-M700 (serv.man26) Service Manual online

AR-M550/M620/M700  SETTING AND ADJUSTMENTS  7 - 43
This adjustment is needed in the following situations: 
• The operation panel has been replaced. 
• U2 trouble has occurred. 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
1) Go through the modes specified in Simulation 65-1. 
2) Press the four cross mark points. 
Pressing the cross mark points correctly results in gray display. When
the touch panel adjustment is complete with the four points pressed,
the sub-number entry screen for simulation reappears. 
If any error is detected, the touch panel returns to adjustment mode. 
Note: Never use something with a sharp tip (such as a needle or pin)
to press the touch panel.
This adjustment is needed in the following situations:
• One or more parts of the DC main power supply unit have been
replaced.
• One or more parts of the DC sub power supply unit have been
replaced.
(24 V supply voltage adjustment)
1) Apply a digital multi-meter to the DC main PWB 24 V line (CN3, 1
pin) and GND (CN3, 4 pin). 
2) Turn RV202 on the DC main power supply PWB so that the volt-
age is 24 V.
(38 V supply voltage adjustment)
3) Apply a digital multi-meter to the DC main PWB 38 V line (CN8, 1
pin) and GND (CN8, 4 pin). 
4) Turn RV201 on the DC main power supply PWB so that the volt-
age is 38 V.
(12 V supply voltage adjustment)
5) Apply a digital multi-meter to the DC sub PWB 12 V line (CN4, 1
pin) and GND (CN4, 6 pin).
6) Turn RV102 on the DC sub power supply PWB so that the voltage
is 12 V.
ADJ 16
Adjusting the touch panel 
coordinates
ADJ 17
Adjusting the supply voltage
SIMULATION 65-1
RV202
(CN3, 4pin) (CN3, 1pin)
GND
+24V
RV201
(CN8, 4pin) (CN8, 1pin)
GND
+38V
RV102
(CN4, 6pin) (CN4, 1pin)
GND
+12V
Page of 43
Display

Download Sharp AR-M700 (serv.man26) Service Manual (Repair Manual)