AR-M700 (serv.man26). Setting and adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 42

Read Sharp AR-M700 (serv.man26) Service Manual online

AR-M550/M620/M700  SETTING AND ADJUSTMENTS  7 - 42
14) Open the SPF paper feed guide to the minimum width position.
15) Select MIN. POSITION using the numeric keypad. 
16) Press the Start key
The minimum width detection level is recognized. 
Note: When each of the above operations has been completed, the
"COMPLETE" message appears; when any of the operations
has failed, the "ERROR" message appears.
This adjustment is needed in the following situations: 
• The original size sensor section has been disassembled. 
• The original size sensor section has been replaced. 
• U2 trouble has occurred. 
• The scanner control PWB has been replaced.
• The EEPROM on the scanner control PWB has been replaced.
1) Go through the modes specified in Simulation 41-1.
2) Gradually turn over the original detection arm unit in the arrow
direction, and loosen the original cover switch actuator adjusting
screw so that the OCSW indicator changes from inverse video to
normal video when the arm unit top reaches a height of 32±0.5mm
from the table glass. Then move the actuator to adjust its position.
(If the original cover switch turns on in improper timing, the original
detection mechanism mail fail to operate correctly.)
1) Go through the modes specified in Simulation 41-2.
2) Open the original cover. With nothing placed on the original table,
select NO ORIGINAL using the numeric keypad. 
3) Press the Start key
This sets the sensor level with no original detected. 
4) Set A3 (11" x 17") paper on the original table, and select A3 ORIG-
INAL using the numeric keypad. 
5) Press the Start key
This sets the sensor level with an original detected. 
When each of the above operations has been completed, the "COM-
PLETE" message appears; when any of the operations has failed, the
"ERROR" message appears.
ADJ 15
Adjusting the original size 
detection (in original table mode)
ADJ 15A
Adjust the detection point of the original 
size sensor (in original table mode)
SIMULATION 41-1
PD SENSOR CHECK..
OCSW  
PD1
  
PD2
  
PD3
  PD4  PD5  PD6  PD7
ADJ 15B
Adjust the sensitivity of the original size 
sensor
Select 2 and press [START] key. 
(Error)
Press [CUSTOM SETTINGS] 
key.
32  5mm
+
-
Original detection
arm unit
Table glass
Original cover switch actuator
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.) 
1. NO ORIGINAL
2. A3 ORIGINAL
1
SIMULATION 41-2
Press [CUSTOM SETTINGS] key. 
Select 1 and 
press [START] key. 
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
A3 ORIGINAL ··· INCOMPLETE
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE
A3 ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
Page of 43
Display

Click on the first or last page to see other AR-M700 (serv.man26) service manuals if exist.