AR-M700 (serv.man26). Setting and adjustments - Sharp Copying Equipment Service Manual (repair manual). Page 41

Read Sharp AR-M700 (serv.man26) Service Manual online

AR-M550/M620/M700  SETTING AND ADJUSTMENTS  7 - 41
2) Open the paper feed guide to the maximum width position. 
3) Select MAX. POSITION using the numeric keypad. 
4) Press the Start key. 
The maximum width detection level is recognized. 
5) Press the CUSTOM SETTINGS key. 
6) Open the paper feed guide to the minimum width position.
7) Select MIN. POSITION using the numeric keypad. 
8) Press the Start key. 
The minimum width detection level is recognized. 
Note: When each of the above operations has been completed, the
"COMPLETE" message appears; when any of the operations
has failed, the "ERROR" message appears.
This adjustment is needed in the following situations: 
• The paper feed tray section has been disassembled. 
• The paper feed tray unit has been replaced. 
• U2 trouble has occurred. 
• The scanner PWB has been replaced. 
• The EEPROM on the scanner PWB has been replaced. 
1) Go through the modes specified in Simulation 53-6. 
2) Open the SPF paper feed guide to the maximum width position.
3) Select MAX. POSITION using the numeric keypad. 
4) Press the Start key. 
The maximum width detection level is recognized. 
5) Press the CUSTOM SETTINGS key.
6) Open the SPF paper feed guide to the width for the A4R size.
7) Select POSITION 1 using the numeric keypad. 
8) Press the Start key
The A4R width detection level is recognized. 
9) Press the CUSTOM SETTINGS key. 
10) Open the SPF paper feed guide to the width for the A5R size.
11) Select POSITION 2 using the numeric keypad. 
12) Press the Start key. 
The A5R width detection level is recognized. 
13) Press the CUSTOM SETTINGS key.
ADJ 14C
Adjust the paper width sensor for the 
SPF paper feed tray
Select 4, and press [START] key.
Press [CUSTOM SETTINGS] 
key.
1
Select 2, and press [START] key.
Select 3, and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or “ERROR”)
Select 1, and 
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or “ERROR”)
Page of 43