AR-FN1 (serv.man7). ARFN1 Service Manual-Adjustment - Sharp Copying Equipment Service Manual (repair manual). Page 8

Read Sharp AR-FN1 (serv.man7) Service Manual online

8. Tray 3 upper limit solenoid 
Slide the upper limit sensor unit 2) in the direction indicated by the
arrow and remove it.
[Adjustment and precautions in setting]
1) Adjust the distance from the end A of the installation plate 6) to
the actuator B for 8 mm, with the solenoid fully pulled. Secure the
solenoid with the screw 4).
2) Use caution to align the notch C of the upper limit sensor unit 2
with the notch D of the rear edge reinforcement plate when secur-
ing the upper limit sensor unit 2 with the screw 1). (See the figure
below.)
P
1)
2)
3)
4)
5)
6)
As a rough guide, screw so
that the edges of solenoid
mounting plate 6) are
matched.
Line
A
B
4)
8mm
D
C
6)
6 – 6