ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 23

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 22 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
5.2 
Electric strength 
5.2.1 
General 
(see appended table 5.2)  
5.2.2 
Test procedure  
(see appended table 5.2)  
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal 
operation 
Output overload test, the most 
unfavorable load test. 
(see appended table 5.3) 
5.3.2 
Motors 
No motors. 
N/A 
5.3.3 
Transformers 
With the shorted o/p of the 
transformer, no high 
temperature of the transformer 
was recorded. 
Results of the short-circuit tests 
see appended table 5.3 and 
Annex C. 
5.3.4 
Functional insulation .............................................:  Method c). Test results see 
appended table 5.3. 
5.3.5 
Electromechanical components 
No electromechanical 
component provided. 
N/A 
5.3.6 
Simulation of faults 
Results see appended table. 
5.3.7 
Unattended equipment 
None of the listed components 
was provided. 
N/A 
5.3.8 
Compliance criteria for abnormal operating and 
fault conditions 
No fire propagated beyond the 
equipment. No molten metal 
was emitted. Electric strength 
test primary to SELV was 
passed. 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
No TNV.  
N/A 
 
Test voltage (V)  ...................................................:   
 
 
Current  in the test circuit (mA) ............................:   
 
6.1.2.2 
Exclusions.............................................................:   
N/A 
 
 
 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
N/A 
6.2.1 
Separation requirements 
No TNV. 
N/A 
Page of 78