Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 22 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
5.2
Electric strength
P
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
Output overload test, the most
unfavorable load test.
unfavorable load test.
(see appended table 5.3)
P
5.3.2
Motors
No motors.
N/A
5.3.3
Transformers
With the shorted o/p of the
transformer, no high
temperature of the transformer
was recorded.
transformer, no high
temperature of the transformer
was recorded.
Results of the short-circuit tests
see appended table 5.3 and
Annex C.
see appended table 5.3 and
Annex C.
P
5.3.4
Functional insulation .............................................: Method c). Test results see
appended table 5.3.
P
5.3.5
Electromechanical components
No electromechanical
component provided.
component provided.
N/A
5.3.6
Simulation of faults
Results see appended table.
P
5.3.7
Unattended equipment
None of the listed components
was provided.
was provided.
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
No fire propagated beyond the
equipment. No molten metal
was emitted. Electric strength
test primary to SELV was
passed.
equipment. No molten metal
was emitted. Electric strength
test primary to SELV was
passed.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
No TNV.
N/A
Test voltage (V) ...................................................:
Current in the test circuit (mA) ............................:
6.1.2.2
Exclusions.............................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
No TNV.
N/A
Click on the first or last page to see other ON STAGE III IIIP (serv.man2) service manuals if exist.