Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 17 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
3.4.2
Disconnect devices
Plug of this direct plug-in
equipment was used as
disconnected device.
equipment was used as
disconnected device.
P
3.4.3
Permanently connected equipment
Not permanently connected
equipment.
equipment.
N/A
3.4.4
Parts which remain energized
There is no parts remained with
hazardous voltage or energy in
the equipment when SPS is
separated from AC mains.
hazardous voltage or energy in
the equipment when SPS is
separated from AC mains.
P
3.4.5
Switches in flexible cords
No flexible cords.
N/A
3.4.6
Single-phase equipment and d.c. equipment
The mains plug disconnects
both poles simultaneously.
both poles simultaneously.
P
3.4.7
Three-phase equipment
Single phase equipment.
N/A
3.4.8
Switches as disconnect devices
See sub-clause 3.4.2.
N/A
3.4.9
Plugs as disconnect devices
See sub-clause 3.4.2.
N/A
3.4.10
Interconnected equipment
No interconnections using
hazardous voltages.
hazardous voltages.
N/A
3.4.11
Multiple power sources
Only one supply connection
provided.
provided.
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
This power supply is not
considered for connection to
TNV.
considered for connection to
TNV.
P
3.5.2
Types of interconnection circuits ..........................: Interconnection circuits of
SELV through the connector.
No ELV interconnection
circuits.
No ELV interconnection
circuits.
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection
N/A
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10°
Direct plug-in equipment.
N/A
Test: force (N).......................................................:
N/A
4.2
Mechanical strength
P
4.2.1
General
See below. After tests, unit
comply with 2.1.1, 2.6.1, 2.10
and 4.4.1.
comply with 2.1.1, 2.6.1, 2.10
and 4.4.1.
P
4.2.2
Steady force test, 10 N
10N applied to components
other than parts serving as an
enclosure.
other than parts serving as an
enclosure.
P