ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 18

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 17 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
3.4.2 
Disconnect devices 
Plug of this direct plug-in 
equipment was used as 
disconnected device. 
3.4.3 
Permanently connected equipment 
Not permanently connected 
equipment. 
N/A 
3.4.4 
Parts which remain energized 
There is no parts remained with 
hazardous voltage or energy in 
the equipment when SPS is 
separated from AC mains. 
3.4.5 
Switches in flexible cords 
No flexible cords. 
N/A 
3.4.6 
Single-phase equipment and d.c. equipment 
The mains plug disconnects 
both poles simultaneously. 
3.4.7 
Three-phase equipment 
Single phase equipment. 
N/A 
3.4.8 
Switches as disconnect devices 
See sub-clause 3.4.2. 
N/A 
3.4.9 
Plugs as disconnect devices 
See sub-clause 3.4.2. 
N/A 
3.4.10 
Interconnected equipment 
No interconnections using 
hazardous voltages. 
N/A 
3.4.11 
Multiple power sources 
Only one supply connection 
provided. 
N/A 
 
3.5 
Interconnection of equipment 
3.5.1 
General requirements 
This power supply is not 
considered for connection to 
TNV. 
3.5.2 
Types of interconnection circuits ..........................:  Interconnection circuits of 
SELV through the connector. 
No ELV interconnection 
circuits. 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnection 
N/A 
 
PHYSICAL REQUIREMENTS 
4.1 
Stability 
N/A 
 
Angle of 10° 
Direct plug-in equipment. 
N/A 
 
Test: force (N).......................................................:   
N/A 
 
 
 
 
4.2 
Mechanical strength 
4.2.1 
General 
See below. After tests, unit 
comply with 2.1.1, 2.6.1, 2.10 
and 4.4.1. 
4.2.2 
Steady force test, 10 N 
10N applied to components 
other than parts serving as an 
enclosure. 
Page of 78
Display