Page 18 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
4.2.3
Steady force test, 30 N
No internal enclosure.
N/A
4.2.4
Steady force test, 250 N
250N applied to outer
enclosure. No energy or other
hazards.
enclosure. No energy or other
hazards.
P
4.2.5
Impact test
Direct plug-in equipment.
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test
No hazard as result from drop
test.
test.
P
4.2.7
Stress relief test
After 7 hours at temperature of
75°C and cooling down to room
temperature, no shrinkage,
distortion or loosening any
enclosure part was noticeable
on the adapter.
75°C and cooling down to room
temperature, no shrinkage,
distortion or loosening any
enclosure part was noticeable
on the adapter.
Test was performed for all
sources of enclosure material.
sources of enclosure material.
P
4.2.8
Cathode ray tubes
No CRT provided.
N/A
Picture tube separately certified ...........................:
N/A
4.2.9
High pressure lamps
No High pressure lamps
provided.
provided.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) .....: Direct plug-in equipment.
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and /or smoothed.
rounded and /or smoothed.
P
4.3.2
Handles and manual controls; force (N) ...............: No handles or controls provided.
N/A
4.3.3
Adjustable controls
No controls provided.
N/A
4.3.4
Securing of parts
No connection likely to be
exposed to mechanical stress is
provided in unit.
exposed to mechanical stress is
provided in unit.
P
4.3.5
Connection of plugs and sockets
No mismating of connectors,
plugs or sockets possible.
plugs or sockets possible.
P
4.3.6
Direct plug-in equipment
The prevention of imposing to
undue strain on the socket-
outlet was done by construction
of the plug of adaptor.
undue strain on the socket-
outlet was done by construction
of the plug of adaptor.
For British plug: 0.07Nm;
For Australian plug: 0.08Nm;
For Japan plug: 0.07Nm.
P