IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
4.2.3 
Steady force test, 30 N 
No internal enclosure. 
N/A 
4.2.4 
Steady force test, 250 N 
250N applied to outer 
enclosure. No energy or other 
hazards. 
4.2.5 
Impact test 
Direct plug-in equipment. 
N/A 
 
Fall test 
 
N/A 
 
Swing test 
 
N/A 
4.2.6 
Drop test 
No hazard as result from drop 
test. 
4.2.7 
Stress relief test 
After 7 hours at temperature of 
75°C and cooling down to room 
temperature, no shrinkage, 
distortion or loosening any 
enclosure part was noticeable 
on the adapter. 
Test was performed for all 
sources of enclosure material. 
4.2.8 
Cathode ray tubes 
No CRT provided. 
N/A 
 
Picture tube separately certified ...........................:   
N/A 
4.2.9 
High pressure lamps 
No High pressure lamps 
provided. 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  .....:  Direct plug-in equipment. 
N/A 
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
All edges and corners are 
rounded and /or smoothed. 
4.3.2 
Handles and manual controls; force (N) ...............:  No handles or controls provided. 
N/A 
4.3.3 
Adjustable controls  
No controls provided. 
N/A 
4.3.4 
Securing of parts 
No connection likely to be 
exposed to mechanical stress is 
provided in unit. 
4.3.5 
Connection of plugs and sockets 
No mismating of connectors, 
plugs or sockets possible.  
4.3.6 
Direct plug-in equipment 
The prevention of imposing to 
undue strain on the socket-
outlet was done by construction 
of the plug of adaptor. 
For British plug: 0.07Nm; 
For Australian plug: 0.08Nm; 
For Japan plug: 0.07Nm. 