<12014238 001 > 
 
 
Page 2 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Copy of marking plate(s): 
With Euro-plug:                                                              With BS plug: 
            
 
 
With Australian plug:                                                   With Japanese plug: 
 
        
 
 
These are representative labels, the others are identical to them except the model number and ratings. 
 
Summary of testing: 
The sample(s) tested complies with the requirements of IEC 60950-1: 2001. 
Compliance with the National requirements of “(AT=Austria, AU=Australia, BE=Belgium, CH=Switzerland, 
DE=Germany, DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, GR=Greece, HU=Hungary, 
IL=Israel, IT=Italy, JP=Japan, NL=The Netherlands, NO=Norway, PL=Poland, SE=Sweden, SI=Slovenia, 
SK=Slovakia) as given in CB Bulletin CB-Bulletin 109A was also confirmed. 
 
 
<12014238 001 > 
 
 
Page 3 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
Particulars: test item vs. test requirements 
Equipment mobility  .......................................:  Direct plug-in equipment 
Operating condition .......................................:  Continuous 
Mains supply tolerance (%) ...........................:  + 10% / - 10% ( as request of the client) 
Tested for IT power systems  ........................:  Yes, Norway 
IT testing, phase-phase voltage (V)  .............:  230 (only for Norway) 
Class of equipment .......................................:  Class II 
Mass of equipment (kg).................................:  Approx. 0.15kg 
Protection against ingress of water  ..............:  IPX0 
Test case verdicts 
 
Test case does not apply to the test object  ..:  N/A 
Test item does meet the requirement  ..........:  P(ass) 
Test item does not meet the requirement  ....:  F(ail) 
Testing 
 
Date of receipt of test item  ...........................:  Jun. 12, 2006 
Date(s) of performance of test  .....................:  Jun. 12, 2006 – Jun. 16, 2006 
General remarks 
”This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a 
NCB, in accordance with IECEE 02”. 
This report shall not be reproduced except in full without the written approval of the testing laboratory. 
The test results presented in this report relate only to the item(s) tested. 
”(see remark #)" refers to a remark appended to the report. 
"(see Annex #)" refers to an annex appended to the report. 
Throughout this report a point is used as the decimal separator. 
Comments: 
Summary of compliance with National Differences (for explanation of codes see below): 
AT, AU, BE, CH, DE, DK, FI, FR, GB, GR, HU, IL, IT, JP, NL, NO, PL, SE, SI, SK 
 
AT=Austria, AU=Australia, BE=Belgium, CH=Switzerland, DE=Germany, DK=Denmark, FI=Finland, 
FR=France, GB=United Kingdom, GR=Greece, HU=Hungary, IL=Israel, IT=Italy, JP=Japan, NL=The 
Netherlands, NO=Norway, PL=Poland, SE=Sweden, SI=Slovenia, SK=Slovakia 
 
For National Differences see end of this test report. 
Manufacturer: 
Same as applicant. 
Factory: 
Dee Van Electronics (Shenzhen) Co., Ltd. 
The 5
th
 Industrial District, Gongming, Bao An District, Shenzhen, Guangdong 518106, P.R. China 
Other remarks: 
All the requirement of IEC 60950:1999 + Corr. Jan. 2000 have been considered in this report.  
The model is in compliance with the requirements of subclause 2.5 (limited power source). 
 
 
 
<12014238 001 > 
 
 
Page 4 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
General product information: 
Brief description of the test sample:  
1. The equipment models DSA-20R-12 Fa xy are switching power Adapter for supply of information 
technology equipment, output cord is non-detachable. 
2. The top enclosure is secured to bottom enclosure by ultrasonic welding. 
3. Specified maximum ambient temperature is 40°C. 
4. The models DSA-20R-12 FEU 090180, DSA-20R-12 FEU 102204 and DSA-20R-12 FEU 150204 have 
been selected for test, and unless otherwise specified, the model DSA-20R-12 FEU 150204 was tested. 
pin parts of British plug, Japanese plug and Australian plug were molded into the enclosure of plug 
portion. It is impossible to remain in the mains consent after removal of the adapter, details see photo 
document. 
Model difference 
1.  R8, R9, R10, R13, R14, R15, R16, R20, R26, R27, R31, C11, C12, Z4: The parameter of these 
components depend on output power and output voltage. 
 
 
<12014238 001 > 
 
 
Page 5 of 77 
 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
 
 
Model list:  
DSA-20R-12 Fa xy: 
 
INPUT 
OUTPUT 
No 
MODEL 
V, A 
V dc 
Max. A 
Max. W 
T1 sec winding 
(Ф*P*Ts) 
DSA-20R-12 Fa xy 
100–240VAC, 
50/60Hz, 0.7A 
9.0 – 15.0 
2.00 
20.4 
Ф0.45mmx4px7Ts 
 
 
<12014238 001 > 
 
 
Page 6 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
  
GENERAL 
1.5 
Components 
1.5.1 
General 
Components which were found 
to affect safety aspects comply 
with the requirements of this 
standard or within the safety 
aspects of the relevant IEC 
component standards. 
 
Comply with IEC 60950 or relevant component 
standard  
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
Components which are certified 
to IEC and /or national 
standards are used correctly 
within their ratings. 
Components not covered by 
IEC standards are tested under 
the conditions present in the 
equipment. 
1.5.3 
Thermal controls 
No thermal controls provided. 
N/A 
1.5.4 
Transformers 
Transformer used are suitable 
for their intended application 
and comply with the relevant 
requirements of the standard 
and particularly Annex C. 
1.5.5 
Interconnecting cables 
Interconnection o/p cable to 
other device is carrying only 
SELV on an energy level below 
240 VA. 
→ Except for the insulation 
material, there are no further 
requirements for the o/p 
interconnection cable. 
1.5.6 
Capacitors in primary circuits ...............................:  No X capacitor provided. 
N/A 
1.5.7 
Double insulation or reinforced insulation bridged 
by components 
See below. 
N/A 
1.5.7.1 
General 
 
N/A 
1.5.7.2 
Bridging capacitors 
No bridging capacitor used. 
N/A 
1.5.7.3 
Bridging resistors 
No bridging resistor used. 
N/A 
1.5.7.4 
Accessible parts 
See clause 2.4 
N/A 
1.5.8 
Components in equipment for IT power systems 
No such component 
N/A 
 
 
 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
IT power system for Norway 
only, TN power system for 
others  
 
 
<12014238 001 > 
 
 
Page 7 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is the 
operation with the max. 
specified DC-load.  
Results see appended table 
1.6.3 
Voltage limit of hand-held equipment 
Not hand-held equipment. 
N/A 
1.6.4 
Neutral conductor  
Class II equipment without earth 
connection. 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating  
See below. 
 
Rated voltage(s) or voltage range(s) (V)  .............:  AC100-240V  
 
Symbol for nature of supply, for d.c. only .............:  Mains from AC source 
N/A 
 
Rated frequency or rated frequency range (Hz)  ..:  50/60Hz  
 
Rated current (mA or A)  ......................................:  0.7A 
 
Manufacturer’s name or trademark or identification 
mark .....................................................................: 
Not shown / trademark of DVE 
 
Type/model or type reference...............................:  DSA-20R-12 Fa xy 
 
Symbol for Class II equipment only  .....................:  Double square symbol 
provided. 
 
Other symbols ......................................................:  Additional symbols or marking 
does not give rise to 
misunderstanding. 
 
Certification marks ...............................................:  Refer to the copy of the label 
drawings for details. 
1.7.2 
Safety instructions 
"User's Manual" provided that 
contains information regarding 
the maximum ambient 
temperature.  
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment ...................................:  No voltage selector. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions .........................................: 
 
N/A 
1.7.5 
Power outlets on the equipment  ..........................:  No power outlets provided. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .........................: 
Marking adjacent to fuse on 
PCB as: 
F1   T1AL 250VAC 
1.7.7 
Wiring terminals 
See below. 
N/A 
1.7.7.1 
Protective earthing and bonding terminals  ..........:  Class II equipment without earth 
connection. 
N/A 
 
 
<12014238 001 > 
 
 
Page 8 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
1.7.7.2 
Terminal for a.c. mains supply conductors  
Direct plug-in equipment. 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
No d.c. mains supply. 
N/A 
1.7.8 
Controls and indicators 
No safety related switches or 
indicators. 
N/A 
1.7.8.1 
Identification, location and marking  .....................:   
N/A 
1.7.8.2 
Colours   ...............................................................:   
N/A 
1.7.8.3 
Symbols according to IEC 60417 .........................:   
N/A 
1.7.8.4 
Markings using figures  ........................................:   
N/A 
1.7.9 
Isolation of multiple power sources  .....................:  Only one supply from the 
mains. 
N/A 
1.7.10 
IT power distribution systems  
Only for Norway 
1.7.11 
Thermostats and other regulating devices  
No such device. 
N/A 
1.7.12 
Language(s) .........................................................:  Installation instruction in 
English and German. 
Versions in other languages 
have to be provided during the 
corresponding national 
approvals. 
 
1.7.13 
Durability 
The label was subjected to the 
permanence of marking test. 
The label was rubbed with cloth 
soaked with water for 15 sec. 
And then again for 15 sec. With 
the cloth soaked with 
petroleum spirit. 
After this test there was no 
damage to the label. The 
marking on the label did not 
fade. There was no curling nor 
lifting of the label edge. 
1.7.14 
Removable parts 
No removable part. 
N/A 
1.7.15 
Replaceable batteries 
No battery provided. 
N/A 
 
Language(s)..........................................................:   
 
1.7.16 
Operator access with a tool ..................................:  No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
1.7.17 
Equipment for restricted access locations ............:  Not limited for use in restricted 
access locations. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
 
 
<12014238 001 > 
 
 
Page 9 of 77 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.1.1 
Protection in operator access areas  
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. 
2.1.1.1 
Access to energized parts 
See above. 
 
Test by inspection ................................................:  See above. 
 
Test with test finger ..............................................:  See above. 
 
Test with test pin ..................................................:  See above. 
 
Test with test probe  .............................................:  No TNV. 
N/A 
2.1.1.2 
Battery compartments  .........................................:  No battery compartment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance (mm) through insulation 
(see appended table 2.10.5) 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
N/A 
2.1.1.5 
Energy hazards ....................................................:  Energy does not exceed 240VA 
between any two points in 
accessible parts (o/p connector 
of secondary circuit). Results 
see appended table 2.1.1.5. No 
energy hazard in operator 
access area. 
2.1.1.6 
Manual controls 
No manual controls. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
There is no capacitor connected 
to the mains circuit. 
N/A 
 
Time-constant (s); measured voltage (V) .............:   
 
2.1.2 
Protection in service access areas 
No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
2.1.3 
Protection in restricted access locations 
Not limited for use in restricted 
access locations. 
N/A 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
The secondary circuits were 
tested as SELV. See 2.2.1 to 
2.2.4. 
2.2.2 
Voltages under normal conditions (V) ..................:  Between any conductor of the 
SELV circuits 42.4 V peak or 
60 V d.c. are not exceeded.      
See appended table 2.2.2. 

Download JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate

Here you can view online and download JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate in PDF. ON STAGE III IIIP (serv.man2) emc - cb certificate will guide through the process and help you recover, restore, fix, disassemble and repair JBL ON STAGE III IIIP (serv.man2) Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.