Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online
<12014238 001 >
Page 19 of 77
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
Dimensions (mm) of mains plug for direct plug-in : (See attached partial test
reports)
P
Torque and pull test of mains plug for direct
plug-in; torque (Nm); pull (N) ................................:
plug-in; torque (Nm); pull (N) ................................:
See above.
P
4.3.7
Heating elements in earthed equipment
No heating elements provided.
N/A
4.3.8
Batteries
No batteries provided.
N/A
4.3.9
Oil and grease
No heating elements provided.
N/A
4.3.10
Dust, powders, liquids and gases
Equipment in intended use not
considered to be exposed to
these.
considered to be exposed to
these.
N/A
4.3.11
Containers for liquids or gases
No container for liquid or gas.
N/A
4.3.12
Flammable liquids.................................................: No such flammable liquid.
N/A
Quantity of liquid (l) ...............................................:
N/A
Flash point (°C).....................................................:
N/A
4.3.13
Radiation; type of radiation ..................................: No optical radiation present.
N/A
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
Measured radiation (pA/kg) .................................:
Measured high-voltage (kV) ................................:
Measured focus voltage (kV) ...............................:
CRT markings .....................................................:
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification ........................................................:
classification ........................................................:
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ......:
N/A
4.3.13.5
Laser (including LEDs)
No optical radiation present.
N/A
Laser class ...........................................................:
4.3.13.6
Other types ..........................................................:
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No moving parts.
N/A
4.4.2
Protection in operator access areas
N/A
4.4.3
Protection in restricted access locations
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
P
4.5.1
Maximum temperatures
See appended table 4.5.1.
P