IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
 
N/A 
6.2.2.2 
Steady-state test 
 
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
N/A 
 
Max. output current (A) .........................................:  No TNV. 
 
 
Current limiting method ........................................:   
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
N/A 
7.1 
Protection of cable distribution system service 
persons, and users of other equipment 
connected to the system, from hazardous 
voltages in the equipment 
Not connected to cable 
distribution system 
N/A 
7.2 
Protection of equipment users from overvoltages 
on the cable distribution system 
 
N/A 
7.3 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.3.1 
General 
 
N/A 
7.3.2 
Voltage surge test 
 
N/A 
7.3.3 
Impulse test 
 
N/A 
 
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE 
A.1 
Flammability test for fire enclosures of movable equipment having a total mass 
exceeding 18 kg, and of stationary equipment (see 4.7.3.2) 
N/A 
A.1.1 
Samples................................................................:   
 
 
Wall thickness (mm) .............................................:   
 
A.1.2 
Conditioning of samples; temperature (°C) ..........:   
N/A 
A.1.3 
Mounting of samples ............................................:   
N/A 
A.1.4 
Test flame (see IEC 60695-11-3) 
 
N/A 
 
Flame A, B, C or D ...............................................:   
 
A.1.5 
Test procedure 
 
N/A 
A.1.6 
Compliance criteria 
 
N/A 
 
Sample 1 burning time (s) ....................................:   
 
 
Sample 2 burning time (s) ....................................:   
 
 
Sample 3 burning time (s) ....................................:   
 
A.2 
Flammability test for fire enclosures of movable equipment having a total mass not 
exceeding 18 kg, and for material and components located inside fire enclosures 
(see 4.7.3.2 and 4.7.3.4) 
Page of 78