IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.:IECEN60950_1B
TRF originator: SGS Fimko
3.1.1
Current rating and overcurrent protection
P
3.1.2
Protection against mechanical damage
Wires do not touch sharp
edges which could damage the
insulation and cause hazard.
edges which could damage the
insulation and cause hazard.
P
3.1.3
Securing of internal wiring
The internal wiring are secured
by solder pins or tubing so that
loosening of the terminal
connections is unlikely.
by solder pins or tubing so that
loosening of the terminal
connections is unlikely.
P
3.1.4
Insulation of conductors
The insulation of the individual
conductors are suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
(see appended table 5.2)
conductors are suitable for the
application and the working
voltage. For the insulation
material see 3.1.1.
(see appended table 5.2)
P
3.1.5
Beads and ceramic insulators
Not used.
N/A
3.1.6
Screws for electrical contact pressure
No such screws provided.
N/A
3.1.7
Insulating materials in electrical connections
All current carrying connections
are metal to metal.
are metal to metal.
N/A
3.1.8
Self-tapping and spaced thread screws
Not used.
N/A
3.1.9
Termination of conductors
All conductors are reliable
secured.
secured.
P
10 N pull test
Force of 10 N applied to the
termination points of the
conductors.
termination points of the
conductors.
P
3.1.10
Sleeving on wiring
No sleeving used to provide
supplementary insulation.
supplementary insulation.
N/A
3.2
Connection to an a.c. mains supply or a d.c. mains supply
P
3.2.1
Means of connection ............................................: A mains plug, that is part of
direct plug-in equipment
P
3.2.1.1
Connection to an a.c. mains supply
See above
P
3.2.1.2
Connection to a d.c. mains supply
AC Source
N/A
3.2.2
Multiple supply connections
Only one supply connection.
N/A
3.2.3
Permanently connected equipment
Not permanently connected
equipment.
equipment.
N/A