Page 8 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
b) Touch current measured from terminal devices
using the network in annex D ........................... :
See table 9.1
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
1 mm x 20 mm test pin (10 N); test probe D of
IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s ...................................................................... :
withdrawal of the mains plug; voltage (V) after
2 s ...................................................................... :
N/A
If C is not greater than 0,1 μF no test needed
P
9.1.7
Enclosure sufficiently resistant to external force
P
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool
for 5 s (100 or 250 N) ........................................ :
for 5 s (100 or 250 N) ........................................ :
250N P
9.2
No hazard 2s after removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min.
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
after surge test for basic and 4 MΩ min. for
reinforced insulation .......................................... :
N/A
10.2
Humidity treatment 48 h or 120 h ..................... : Both 48 and 120h ( see also page 42 )
P
10.3
Insulation resistance and dielectric strength
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
No hazard from softening solder
P
No flaming more than 10s
P