HT-SL70 (serv.man7). HDMI switching problem and background noise - Sharp Audio Technical Bulletin (repair manual)

ht-sl70 (serv.man7) technical bulletin
Model
HT-SL70 (serv.man7)
Pages
6
Size
290.11 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
Audio / Home Theatre / HDMI switching problem and background noise
File
ht-sl70-sm7.pdf
Date

Read Sharp HT-SL70 (serv.man7) Technical Bulletin online

AUD 2012 02 01 
 
Date of Issue:         8
th 
February 2012 
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 1 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference – RG20120119
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
MODELS 
HT-SL50 HT-SL70  
 
 
 
 
 
 
 
SYMPTOM  
HDMI switching issue and back ground noise on the HT-SL70.
 
 
CAUSE 
Software timing issues and capacitor needs removal (HT-SL70). 
 
ACTION 
Follow the instructions below to remove C622 on HT-SL70 and how to update the 
software. 
 
 
 
If the loan of programming tools is required please log your request on the Technical 
Web site. 
 A charge will be made for those not returned within 28 days. 
 
HT-SL70 only, C622 removal. 
 
                                  
 
 
1.  Remove the 4 screw at the back of the unit. 
 
 
 
2.  Remove the 5 x bottom screws as shown above 
 
 
 
AUD 2012 02 01 
 
Date of Issue:         8
th 
February 2012 
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 2 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference – RG20120119
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
 
3.  Cut Cable Tie to enable easier removal of Chassis. 
 
 
 
4.  Locate C622 and remove ( Green Disc capacitor ). 
 
 
 
 
5.  Re-address cable, fit new cable tie, relocate the chassis and refit screws. 
 
 
 
AUD 2012 02 01 
 
Date of Issue:         8
th 
February 2012 
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 3 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference – RG20120119
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
 
Software Update for both units. 
 
Reflash both CPU and slave MPU software. 
 
Load onto your PC, down loadable from the Technical Web site the “EPFlash” 
software and also save to a known location the “HDMI update software”. 
 
1.  Connect the mains supply and have the unit in stand-by ( Red light on ). 
 
2.  Connect the Software writer jig as shown below. 
 
Figure 1. Jig Red light should be iluminated. 
 
3.  Press the RH tip button. 
 
 
Figure 2. R.H. Button press to start programming cycle. 
AUD 2012 02 01 
 
Date of Issue:         8
th 
February 2012 
         
Classification: 
White 
AUDIO TECHNICAL BULLETIN
 
Page 4 of 6 
 
 
Sharp Electronics (UK) Limited 
Reference – RG20120119
 
Revision  - 1 
 
White – Carry out as required 
Yellow – Carry out as required and whenever the unit comes in for service 
 Red – Carry out on all units   
 
4.  Yellow light should iluminate to show unit in programming mode 
 
 
 
5.  When operation is completed Blue light will iluminate. 
 
 
 
6.  When completed un-plug the mains supply Leave programming jig in place . 
 
 
 
 
 
 
 
 
Page of 6
Display

Download Sharp HT-SL70 (serv.man7) Technical Bulletin

Here you can read online and download Sharp HT-SL70 (serv.man7) Technical Bulletin in PDF. HT-SL70 (serv.man7) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp HT-SL70 (serv.man7) Home Theatre. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.