Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ......................... :
N/A
14.2
Capacitors and RC units
Capacitors separately approved
N/A
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ................................................................ :
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ................................................................ :
Across mains switch
P
14.2.3
Capacitors operating at mains frequency but
not connected to the mains: tests for X2 .......... :
not connected to the mains: tests for X2 .......... :
N/A
14.2.5
a)
a)
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B
or better ................................................................
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B
or better ................................................................
N/A
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source
than table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or better ........... :
mounted closer to a potential ignition source
than table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or better ........... :
N/A
Shielded by a barrier per Table 21 .................... :
N/A
14.3 Inductors
and
windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ......................... :
manufacturer's name and type ......................... :
Transtec TT0869803320
P
Transformers and inductors separately
approved ............................................................ :
approved ............................................................ :
N/A
14.3.2 General
14.3.3
Constructional requirements (complete
appended tables or include manufacturers
constructional insulation descriptions)
appended tables or include manufacturers
constructional insulation descriptions)
P
14.3.3.1
Clearances and creepage distances comply
with clause 13
with clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
Prim.-sec: 8.15mm
P
Coil formers and partition walls ≥ 0,4 mm
1.4mm P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A