Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online
Page 4 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ........................... : Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the
test box
test box
No N/A
5 MARKING
Comprehensible and easily discernible
P
Permanent
durability against water and
petroleum spirit
P
5.1 a), b)
Identification, maker, model .............................. :
BALBOA SUB 10/230
P
c)
Class II symbol if applicable
P
d), e)
Rated supply voltage and symbol .................... : 220-230V
∼
P
f)
Frequency if safety dependant
50/60Hz
P
g), h), i)
Rated current or power consumption ............... : 220W
P
5.2
a)
Earth terminal
N/A
b)
Hazardous live terminals
N/A
c)
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
Only in schematic diagram
P
5.4 Instructions
for
use
5.4.1
a)
Mains powered equipment not exposed to
dripping or splashing. Warning concerning
objects filled with liquid, etc.
dripping or splashing. Warning concerning
objects filled with liquid, etc.
P
b)
Hazardous live terminals, instructions for wiring
N/A
c)
Instructions for replacing lithium battery
N/A
Instructions for modem if fitted
N/A
d)
Class I earth connection warning
N/A
e)
Instructions for multimedia system connection
N/A
f)
Special stability warning for fixed installation
N/A
5.4.2
Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and
markings
mains switch location, accessibility and
markings
P
Instructions for permanently connected
equipment
equipment
N/A
Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.