Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online
Page 12 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
Prim.-iron core: 6.95mm
P
Coil formers and partition walls = 0,4 mm
1.4mm P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
N/A
Winding wires connected to protective earth
have adequate current-carrying capacity
have adequate current-carrying capacity
N/A
14.4 High
voltage
components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N/A
14.5 Protective
devices
Protective devices used within their ratings
P
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the
submission
submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
P
14.5.2.2
Correct marking of fuse-links adjacent to
holder ....................................................................
holder ....................................................................
Fuse T1.25A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel .......... : P
14.5.2.4
Not possible to touch hazardous live parts
when replacing fuse-links without the use of a
tool ..................................................................... :
when replacing fuse-links without the use of a
tool ..................................................................... :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
Click on the first or last page to see other BALBOA SUB10 (serv.man2) service manuals if exist.