Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online
Page 9 of 44
Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards
(PCB) exceeding the limits of table 3 by max.
100 K for max. 5 min
(PCB) exceeding the limits of table 3 by max.
100 K for max. 5 min
N/A
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
N/A
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
P
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of parts not subject to the
limits of 11.2.1 to 11.2.5 Table 3 e) "Other
Parts"
limits of 11.2.1 to 11.2.5 Table 3 e) "Other
Parts"
P
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
P
12.1.2
Vibration test (portable, metal, musical amps)
No connection or part which might
impair safety can become loose
impair safety can become loose
P
12.1.3
Impact hammer test
P
Steel ball test (for non-ventilated solid areas)
P
12.1.4
Drop test for portable apparatus where mass ≤
7 kg
7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A