Report Ref No.: 614376
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No.: IEC60065E
TRF Originator: ASTABEAB
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged
with 2 capacitors in series complying with
14.2.1 a)
with 2 capacitors in series complying with
14.2.1 a)
N/A
Reinforced or double insulation being bridged
with a single capacitor complying with 14.2.1 b)
with a single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components
complying with 14.3.4.3
complying with 14.3.4.3
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
This clause is not considered
N/A
Reinforced or double insulation between
circuits operating at voltages between 35 V and
71 V (peak) a.c. or between 60 V and 120 V
d.c. and hazardous live parts at higher voltage
circuits operating at voltages between 35 V and
71 V (peak) a.c. or between 60 V and 120 V
d.c. and hazardous live parts at higher voltage
N/A
Separation by Class II isolating transformer
N/A
Separation by Class I transformer
N/A
Separation by earthed conductive part
N/A
8.8
Double Insulation: the Basic or Supplementary
insulation > 0,4 mm (mm) ................................. :
insulation > 0,4 mm (mm) ................................. :
Primary wires
P
Reinforced insulation > 0,4 mm (mm) .............. : Transformer bobbin
P
Thin sheet insulation used inside the enclosure.
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3 dielectric
any two of which meet 10.3 dielectric
N/A
Reinforced
insulation,
two layers each of which
meet 10.3 dielectric
N/A
Reinforced insulation, three layers any two
which meet 10.3 dielectric
which meet 10.3 dielectric
N/A
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and
accessible parts
internal hazardous live conductors and
accessible parts
Applies to class I appliance
N/A
Secondary Wiring: Adequate insulation
between internal hazardous live parts and
conductors connected to accessible parts
between internal hazardous live parts and
conductors connected to accessible parts
N/A