BALBOA SUB10 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL BALBOA SUB10 (serv.man2) EMC - CB Certificate online

 
Page 5 of 44 
Report Ref No.: 614376 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065E 
 
TRF Originator: ASTABEAB 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1 ..  
N/A 
 
Emission limits under fault conditions  .............. :  
N/A 
 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
 
7.1 
Temperature rises not exceeding specified 
values, any single protective device defeated 
except those of Cl. 7.1 a) and b) 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or 
as a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
 N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage 
setting device, fuse-links or handling drawers 
etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided 
by hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal 
of a cover which can be removed by hand 
 P 
8.5 
Class I equipment 
 
 
 
Basic insulation between hazardous live parts 
and earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying 
with 14.2.1 a) 
 N/A 
8.6 
Class II equipment and Class II constructions within Class I equipment 
Page of 56