Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 66 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
20.1.3
Replace 1st paragraph with: ―Base material of
printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, shall be of
flammability category V-1 or better according to
UL 94.‖
In 2nd paragraph replace ―IEC 60707‖ with ―UL
94‖ and remove exception for printed boards
housed in metal enclosures.
printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, shall be of
flammability category V-1 or better according to
UL 94.‖
In 2nd paragraph replace ―IEC 60707‖ with ―UL
94‖ and remove exception for printed boards
housed in metal enclosures.
In 3rd paragraph replace ―IEC 60707‖ with ―UL
94‖ and delete option to use Clause G.1 of Annex
G.
94‖ and delete option to use Clause G.1 of Annex
G.
P
20.1.4
Replace with: ―Components and parts shall
comply with the relevant flammability category
according to UL 94 as specified in Table 21.
Delete all other text.
comply with the relevant flammability category
according to UL 94 as specified in Table 21.
Delete all other text.
Add: ―Component power supplies complying with
the construction and test requirements of UL
1310, UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.‖
the construction and test requirements of UL
1310, UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.‖
Table 21 - Replace complete table with new table
for ―Flammability categories for components and
parts.‖
for ―Flammability categories for components and
parts.‖
P
20.2.1
Modification: 1st paragraph: ―Fire enclosure
required for 1) circuits and components where the
available power exceeds 15 W, 2) inductors and
windings conductively connected to the mains
and 3) high-voltage products. The fire enclosure
shall comply with the flammability requirements of
Table 22 according to UL 94 and 746C. 2nd, 3rd,
and 4th paragraphs are deleted.
required for 1) circuits and components where the
available power exceeds 15 W, 2) inductors and
windings conductively connected to the mains
and 3) high-voltage products. The fire enclosure
shall comply with the flammability requirements of
Table 22 according to UL 94 and 746C. 2nd, 3rd,
and 4th paragraphs are deleted.
In 5th paragraph replace ―IEC 60707 or clause
G.1 of Annex G‖ with ―UL 94 or UL 746C.‖
G.1 of Annex G‖ with ―UL 94 or UL 746C.‖
Table 22
– Add‖ Flammability categories for fire
enclosures.
P
20.2.2
Revise text to read: ―Internal fire enclosures shall
not have openings that permit accessibility to
components, wiring, connections, or printed
wiring board conductive patterns where the
available power exceeds 15 W and to inductors
and windings conductively connected to the
mains and shall comply with the material
requirements in Table 22. Compliance is checked
by inspection and measurement and using the
jointed test finger.‖
not have openings that permit accessibility to
components, wiring, connections, or printed
wiring board conductive patterns where the
available power exceeds 15 W and to inductors
and windings conductively connected to the
mains and shall comply with the material
requirements in Table 22. Compliance is checked
by inspection and measurement and using the
jointed test finger.‖
N/A
20.2.3
Modification: Outer enclosures shall have a
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
N/A
Click on the first or last page to see other BDS 275 service manuals if exist.