Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 63 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
15.1.2
Delete reference to ―Banana‖ plug in the Note.
N/A
15.1.3.1
Add: ―An audio amplifier having an open-circuit
audio output voltage not limited to 120 V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1
audio output voltage not limited to 120 V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1
–U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1
–
U.21.3.5, or quick-connect terminals, or leads.
Quick Connect Terminal shall comply with the
following:
Quick Connect Terminal shall comply with the
following:
a) Male tabs firmly mounted in place,
b) Mating female connectors shall be provided
with the apparatus,
with the apparatus,
c) Strain Relief Test of Clause 16.5,
d) Installation instructions shall be provided for
assembly of terminal to a conductor and strain
relief,
assembly of terminal to a conductor and strain
relief,
e) Terminals shall be appropriate for use with the
size and type of wire specified.‖
size and type of wire specified.‖
N/A
15.1.3.2
Add: "Audio amplifiers having an audio output not
limited to 120 V that are connected to the mains
by a flexible cord shall have suitable cord or
provision for field installation or a receptacle for
plug-in connections."
limited to 120 V that are connected to the mains
by a flexible cord shall have suitable cord or
provision for field installation or a receptacle for
plug-in connections."
N/A
15.2
Add after 3rd paragraph: ―The earthing conductor
in a supply cord, or in an interconnecting cable
shall have an equivalent or larger cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
in a supply cord, or in an interconnecting cable
shall have an equivalent or larger cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
N/A
15.3.5
Revise 2nd paragraph to read: ―For rated currents
exceeding 13 A, reference is made to Article 310
of the National Electrical Code, ANSI/NFPA 70.‖
exceeding 13 A, reference is made to Article 310
of the National Electrical Code, ANSI/NFPA 70.‖
Table 15 -
Replace with: ―Nominal cross-sectional
area AWG― and modify values.
N/A
15.4
Add: ‖Component power supply adaptors
complying with the construction and test
requirements of UL1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.‖
complying with the construction and test
requirements of UL1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.‖
N/A
16.1
Modification: Mains supply flexible cords shall
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by
the apparatus. Delete references to IEC 602227,
60245 and 60173.
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by
the apparatus. Delete references to IEC 602227,
60245 and 60173.
Table 17A - Add: Types of cords and cord lengths
for various types of apparatus.
for various types of apparatus.
UL approved power cord used
P