Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
16.2
An integral earthing conductor shall be at least
the same size as the other cord conductors.
Substitute ―IEC 60950, table 3B‖ with ―Article 400
of the National Electrical Code‖.
the same size as the other cord conductors.
Substitute ―IEC 60950, table 3B‖ with ―Article 400
of the National Electrical Code‖.
Table 18
– Replace with ―Wire sizes of external
flexible cords‖ Upper current limit in column 1
increased from 16 to 30 A and ―AWG‖ wire sizes
added.
increased from 16 to 30 A and ―AWG‖ wire sizes
added.
N/A
16.3
Add: c) Flexible cords not complying with 16.1,
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
N/A
17.8
Expanded to include all cart/stand parts supplied
by the manufacturer, such as casters and
brackets.
by the manufacturer, such as casters and
brackets.
Suitable assembly instructions required. Add:
"Relevant fixing means are not required when
installation is to be done by a skilled person."
"Relevant fixing means are not required when
installation is to be done by a skilled person."
N/A
17.10
Add: Aluminum conductors used as internal
wiring shall be terminated by a method capable of
being used in the combination of metals involved
at the connection point.
wiring shall be terminated by a method capable of
being used in the combination of metals involved
at the connection point.
N/A
17.11
Add: An accessory shall be investigated to
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory is provided with
installation instructions.
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory is provided with
installation instructions.
P
17.11.1
Add: The installation of an accessory of a skilled
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
N/A
18
Modification: Non-intrinsically protected picture
tubes shall comply with 18.1, 18.2.2 and 18.3.
tubes shall comply with 18.1, 18.2.2 and 18.3.
Intrinsically protected picture tubes shall comply
with UL 1418 or UL 61965.
with UL 1418 or UL 61965.
Add: ―A bulb of a picture tube having a face
diameter of 7.5 cm or more shall be mounted in
an enclosure.
diameter of 7.5 cm or more shall be mounted in
an enclosure.
The enclosure shall have no opening that
exceeds 130 mm2 unless the minor dimension of
the opening is 10 mm or less.‖
exceeds 130 mm2 unless the minor dimension of
the opening is 10 mm or less.‖
N/A