BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 124

Read Harman Kardon BDS 275 EMC - CB Certificate online

Page 64 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
16.2 
An integral earthing conductor shall be at least 
the same size as the other cord conductors. 
Substitute ―IEC 60950, table 3B‖ with ―Article 400 
of the National Electrical Code‖. 
Table 18 
– Replace with ―Wire sizes of external 
flexible cords‖ Upper current limit in column 1 
increased from 16 to 30 A and ―AWG‖ wire sizes 
added. 
 
N/A 
16.3 
Add: c) Flexible cords not complying with 16.1, 
used as connection between the apparatus and 
other apparatus used in combination with it, shall 
be marked VW-1. 
 
N/A 
17.8 
Expanded to include all cart/stand parts supplied 
by the manufacturer, such as casters and 
brackets. 
Suitable assembly instructions required. Add: 
"Relevant fixing means are not required when 
installation is to be done by a skilled person." 
 
N/A 
17.10 
Add: Aluminum conductors used as internal 
wiring shall be terminated by a method capable of 
being used in the combination of metals involved 
at the connection point. 
 
N/A 
17.11 
Add: An accessory shall be investigated to 
determine that: a) The accessory, and the 
combination of the accessory and the apparatus 
shall present no hazard in the sense of this 
standard and b) The accessory is provided with 
installation instructions. 
 
17.11.1 
Add: The installation of an accessory of a skilled 
person shall be such that: a) The mechanical 
positioning is accomplished by means of tools 
normally available or by means of special tools 
provided by the organization responsible for 
providing the apparatus as part of the installation 
kit, and b) The electrical connections are made by 
using existing terminals and connections in the 
apparatus or the building wiring. 
 
N/A 
18 
Modification: Non-intrinsically protected picture 
tubes shall comply with 18.1, 18.2.2 and 18.3. 
Intrinsically protected picture tubes shall comply 
with UL 1418 or UL 61965. 
Add: ―A bulb of a picture tube having a face 
diameter of 7.5 cm or more shall be mounted in 
an enclosure. 
The enclosure shall have no opening that 
exceeds 130 mm2 unless the minor dimension of 
the opening is 10 mm or less.‖ 
 
N/A 