Page 61 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
14.4.4 
Add: High voltage isolation component insulation 
test. 
 
N/A 
14.5.1 
Delete reference to 14.5.1.3. 
 
N/A 
14.5.1.1 
Replace text with: Thermal cutouts shall comply 
with UL 873, UL 8730-2-9 or UL 60730-2-9. 
 
N/A 
14.5.1.2 
Replace text with: "Thermal links shall comply 
with UL 1020 or IEC 60691." 
 
N/A 
14.5.1.3 
Delete 
 
N/A 
14.5.2.1 
Modification: Fuse links shall comply with UL 248-
14 
 
14.5.2.2 
Delete reference to IEC 60127 and breaking 
capacity marking requirements 
 
14.5.3 
Add: As an option, a PTC thermistor may comply 
with UL 1434. Delete the 3rd and 4th paragraphs. 
 
N/A 
14.5.3A 
Add: Protective devices connected to the mains 
shall have adequate breaking capacity and 
comply with UL 873, UL 1416, UL 1417 or UL 
2111 as applicable. 
 
N/A 
14.5.4 
Reference to fuse-links is deleted 
 
N/A 
14.6.1 
Add: ―Switches and relays shall comply with UL 
1054, UL 61058-1 or UL 508 as applicable. Mains 
switch or relay shall be rated for the total current 
through the switch or relay contacts.‖ 
Replace remaining text with: ―A rating of a mains 
switch or relay, provided on a audio apparatus 
intended for commercial use, is to be equal to or 
greater than the maximum steady state current it 
controls under normal 
operating conditions except the audio output is 
adjusted to 1/3 maximum undistorted output or at 
1/3 of the manufacturer‘s rated output power, 
whichever is greater.‖ 
 
14.6.2, 
14.6.3, 
14.6.4 
deleted. 
 
N/A 
14.6.5 
Modification: A switch or relay that controls a 
mains socket-outlet shall have a rating equal to 
the rated current consumption of the apparatus 
plus the current rating of the socket-outlet. 
 
N/A 
14.6.6 
Add: A mains switch shall comply with (a), (b) or 
(c). The contacts of a mains relay shall comply 
with (a), (b) or (d). A switch that controls a mains 
receptacle shall comply with (b) and a relay that 
controls a mains receptacle shall comply with (b) 
or (d). 
 
Page of 127
Display