Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 61 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
14.4.4
Add: High voltage isolation component insulation
test.
test.
N/A
14.5.1
Delete reference to 14.5.1.3.
N/A
14.5.1.1
Replace text with: Thermal cutouts shall comply
with UL 873, UL 8730-2-9 or UL 60730-2-9.
with UL 873, UL 8730-2-9 or UL 60730-2-9.
N/A
14.5.1.2
Replace text with: "Thermal links shall comply
with UL 1020 or IEC 60691."
with UL 1020 or IEC 60691."
N/A
14.5.1.3
Delete
N/A
14.5.2.1
Modification: Fuse links shall comply with UL 248-
14
14
P
14.5.2.2
Delete reference to IEC 60127 and breaking
capacity marking requirements
capacity marking requirements
P
14.5.3
Add: As an option, a PTC thermistor may comply
with UL 1434. Delete the 3rd and 4th paragraphs.
with UL 1434. Delete the 3rd and 4th paragraphs.
N/A
14.5.3A
Add: Protective devices connected to the mains
shall have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
2111 as applicable.
shall have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
2111 as applicable.
N/A
14.5.4
Reference to fuse-links is deleted
N/A
14.6.1
Add: ―Switches and relays shall comply with UL
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.‖
Replace remaining text with: ―A rating of a mains
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.‖
Replace remaining text with: ―A rating of a mains
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal
operating conditions except the audio output is
adjusted to 1/3 maximum undistorted output or at
1/3 of the manufacturer‘s rated output power,
whichever is greater.‖
adjusted to 1/3 maximum undistorted output or at
1/3 of the manufacturer‘s rated output power,
whichever is greater.‖
P
14.6.2,
14.6.3,
14.6.4
14.6.3,
14.6.4
deleted.
N/A
14.6.5
Modification: A switch or relay that controls a
mains socket-outlet shall have a rating equal to
the rated current consumption of the apparatus
plus the current rating of the socket-outlet.
mains socket-outlet shall have a rating equal to
the rated current consumption of the apparatus
plus the current rating of the socket-outlet.
N/A
14.6.6
Add: A mains switch shall comply with (a), (b) or
(c). The contacts of a mains relay shall comply
with (a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
(c). The contacts of a mains relay shall comply
with (a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
P