BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 118

Read Harman Kardon BDS 275 EMC - CB Certificate online

Page 58 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
6.1 
Starting from second paragraph replace all by: 
"Compliance is checked in accordance with the 
requirements in the U.S. Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, and 1020.10 by 
measuring the radiation produced by the 
apparatus employing a design center chassis." 
 
N/A 
6.2 
Starting from second paragraph replace all by: 
"Apparatus shall be classified and labeled in 
accordance with the Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, 1040.10 and 1040.11." 
 
6.2.2 
Deleted 
 
N/A 
Table 3 
Temperature limits added for various classes of 
insulation systems. 
Add to Note a): "Materials rated in accordance 
with UL 746B may be used at their rated higher 
temperature.". 
 
7.2 
Add: A material temperature rating can be 
accepted in lieu of the softening temperature. The 
softening test need not be performed on 
materials used in UL Listed or Recognized parts. 
 
N/A 
8.1 
Add: ―A metal part that is not inherently resistant 
to corrosion shall be protected against corrosion 
when corrosion of that part is capable of 
contributing to or resulting in a risk of fire, shock, 
or injury to persons.‖ 
 
N/A 
8.9.1 
Add: ―Sleeving, tape, tubing, and wire insulation 
are suitable for the conditions of use, such as 
voltageand temperature, and comply with UL 224, 
UL 510, and UL 1441, as applicable.‖ 
 
8.10 
Add: ―Component power supplies and their 
internal insulation complying with the construction 
and test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements on the clause.‖ 
 
N/A 
8.12 
Modification: Conductors and internal wiring 
connecting mains socket-outlets shall comply with 
the wire size requirements in clause 16.2 based 
on the marked rating of the outlet but shall not be 
less than 18 AWG. 
 
8.17 
Add: As an option, winding wire insulation may 
comply with the requirements in UL Subject 2353. 
 
N/A 
8.19.1 
Modification: An all-pole switch or circuit breaker 
is not required to have contact separation of 3 
mm. 
 
N/A 