Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
6.1
Starting from second paragraph replace all by:
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
N/A
6.2
Starting from second paragraph replace all by:
"Apparatus shall be classified and labeled in
accordance with the Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, 1040.10 and 1040.11."
"Apparatus shall be classified and labeled in
accordance with the Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, 1040.10 and 1040.11."
P
6.2.2
Deleted
N/A
Table 3
Temperature limits added for various classes of
insulation systems.
insulation systems.
Add to Note a): "Materials rated in accordance
with UL 746B may be used at their rated higher
temperature.".
with UL 746B may be used at their rated higher
temperature.".
P
7.2
Add: A material temperature rating can be
accepted in lieu of the softening temperature. The
softening test need not be performed on
materials used in UL Listed or Recognized parts.
accepted in lieu of the softening temperature. The
softening test need not be performed on
materials used in UL Listed or Recognized parts.
N/A
8.1
Add: ―A metal part that is not inherently resistant
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.‖
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.‖
N/A
8.9.1
Add: ―Sleeving, tape, tubing, and wire insulation
are suitable for the conditions of use, such as
voltageand temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.‖
are suitable for the conditions of use, such as
voltageand temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.‖
P
8.10
Add: ―Component power supplies and their
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
N/A
8.12
Modification: Conductors and internal wiring
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
P
8.17
Add: As an option, winding wire insulation may
comply with the requirements in UL Subject 2353.
comply with the requirements in UL Subject 2353.
N/A
8.19.1
Modification: An all-pole switch or circuit breaker
is not required to have contact separation of 3
mm.
is not required to have contact separation of 3
mm.
N/A