BDS 275 - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 120

Read Harman Kardon BDS 275 EMC - CB Certificate online

Page 60 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
US  United States of America 
US 
12.1.6 
Add: Handle strength test requirements. 
 
N/A 
12.7 
Add: Wall and ceiling mounting means test 
requirements. 
 
N/A 
12.8 
Add test for enclosures, barriers, components 
and leads that rely on adhesive. 
 
N/A 
12.8.1 
Add test for conductive labels secured in place by 
adhesive. 
 
N/A 
13 
Add: ‖Component power supplies and their power 
transformers complying with the construction and 
test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements on the clause.‖ 
 
N/A 
13.4 
Modification: A material group is verified 
according to UL 746A. 
 
13.5.1 
Change standard reference from IEC 60249-2 to 
UL 796. 
 
N/A 
13.5.2 
Modification: Coated printed wiring boards shall 
comply with requirements in UL 746C 
Table 12 - Note 3 revised to refer to UL 746A. 
 
N/A 
14 
Delete Note 2. Add reference to Annex Y and 
additional component requirements. 
 
14.1, 
14.2, 
14.3 
Add: Component power supplies and their 
resistors complying with the construction 
and test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the 
test requirements of Clause 14.1 and 14.2.1 
– 
14.5.2. 
 
14.2.1, 
14.2.2 
Add: ―As an alternative a component such as a 
capacitor, a combination capacitor and resistor, a 
varistor, or a suppressor shall comply with the 
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.‖ 
 
14.2.4 
Replace text with: ―Components subjected to the 
requirements in 14.2.1 and 14.2.2 shall also 
comply with the enclosure requirements of UL 
1414.‖ 
 
N/A 
14.4 
Add to Note 2: 
―High voltage materials shall be 
rated 94V-
2 minimum.‖ 
Modification: Compliance is checked by meeting 
requirements for category V-2 according to UL 
94. Moreover the requirements are added for 
arcing, component part flame and high-voltage 
isolating component tests. 
 
N/A 
14.4.1 
Replace with High voltage arcing test. 
 
N/A 
14.4.2 
Deleted 
 
N/A 
14.4.3 
Add: High voltage component part flame test. 
 
N/A 
Page of 127
Display