Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 67 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
Figures
Modifications to Figures:
Fig 14 - Illustrates the articulated finger probe.
Fig 15 - Illustrates the shock hazard marking and
associated graphical symbols.
associated graphical symbols.
Fig 16 - Illustrates the shock hazard graphical
symbol.
symbol.
Fig 17 - Illustrates portable cart marking.
Fig 18 - High voltage spacings graph.
Fig 19 - Class 105 insulation aging temperature
graph.
graph.
Fig 20 - Flowchart for horizontal force test.
P
Annex A
Modification: Apparatus intended for outdoor use
or wet locations has any of the following
attributes: a) provided with a means to make it
transportable, b) has a mass less than 35 kg, c)
can be battery operated, d) associated literature
states or implies such use
or wet locations has any of the following
attributes: a) provided with a means to make it
transportable, b) has a mass less than 35 kg, c)
can be battery operated, d) associated literature
states or implies such use
N/A
Add: Apparatus in a), b), or c) above is not
considered for outdoor use or in wet locations if
marked as specified in 5.4.
considered for outdoor use or in wet locations if
marked as specified in 5.4.
N/A
A.5,
A.5.1,
A.5.4.1
A.5.1,
A.5.4.1
deleted.
N/A
A.9.1.1
Add: Touch current test shall be conducted after
the water spray test described in A.11.1.1 and the
touch current shall not be more than 0.5 MIU
when the open-circuit potential between any
accessible part and earth or any other accessible
part is more than 21.2 V peak.
the water spray test described in A.11.1.1 and the
touch current shall not be more than 0.5 MIU
when the open-circuit potential between any
accessible part and earth or any other accessible
part is more than 21.2 V peak.
N/A
A.10,
A10.2,
A.10.2.1,
A.10.2.2
A10.2,
A.10.2.1,
A.10.2.2
Deleted
N/A
A.11.1.1
Add: Apparatus shall be subjected to the water
spray test according to UL 1571.
spray test according to UL 1571.
N/A
A.16.1
Add: Flexible cords shall be suitable for outdoor
use.
use.
N/A
A.20.2.1
Add: Enclosures for an apparatus intended for
permanent outdoor location shall comply with
requirements for Type 3 enclosures in UL 50.
permanent outdoor location shall comply with
requirements for Type 3 enclosures in UL 50.
N/A
Annex B
5th paragraph - add reference to clause 4.2.1.1 in
IEC 62151.
IEC 62151.
Add to 12th paragraph: ―The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.‖
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.‖
N/A