Read Harman Kardon BDS 275 EMC - CB Certificate online
Page 65 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
18.1
All tubes shall be mounted such that the
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
enclosure of the apparatus protects the tube
against the effects of implosion. Delete reference
to clause 18.2.
N/A
18.2,
18.2.1,
18.2.3
18.2.1,
18.2.3
deleted
N/A
19
Add reference to 19.2.1. The test of 19.3 is
conducted on 1) apparatus with direct view CRT
with 48 cm diagonal min., 2) apparatus, other
than a speaker, with a mass greater than 47 kg,
and 3) apparatus, other than a speaker, with a
mass or 25 kg or greater and a height of 1 m or
more. The tests in 19.1, 19.2 and 19.3 shall not
cause the apparatus to overturn. During the test
of 19.2.1, the apparatus shall not slide.
conducted on 1) apparatus with direct view CRT
with 48 cm diagonal min., 2) apparatus, other
than a speaker, with a mass greater than 47 kg,
and 3) apparatus, other than a speaker, with a
mass or 25 kg or greater and a height of 1 m or
more. The tests in 19.1, 19.2 and 19.3 shall not
cause the apparatus to overturn. During the test
of 19.2.1, the apparatus shall not slide.
N/A
19.2.1
Add: Slide test requirements.
N/A
19.3
Replace by Horizontal force stability test
requirements.
requirements.
N/A
Table 20 Add values for horizontal force test
N/A
19.6
Add: ―or equipment rack mounting‖.
N/A
20.1a
Delete
N/A
20.1b
Replace ―IEC 60707‖ with ―UL 94‖
Add: ―-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.‖
Add: ―-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less then 0.25 mm thick.‖
N/A
20.1.2
Revise text to read: ―Sleeving, extruded tubing
and insulation on wiring shall be rated VW-1
under following conditions: a) wiring located in a
circuit that is considered a potential ignition
source‖ or b) wiring not located in a circuit that is
a potential ignition source but is in contact with
wiring located in a circuit that is a potential
ignition source. ‖Tape should be flame retardant.‖
Delete Note and add: ―Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
and insulation on wiring shall be rated VW-1
under following conditions: a) wiring located in a
circuit that is considered a potential ignition
source‖ or b) wiring not located in a circuit that is
a potential ignition source but is in contact with
wiring located in a circuit that is a potential
ignition source. ‖Tape should be flame retardant.‖
Delete Note and add: ―Tape in contact with parts
of circuits that are potential ignition sources shall
be flame retardant.
P